Blind deblurring of spiral CT images-comparative studies on edge-to-noise ratios.
نویسندگان
چکیده
A recently developed blind deblurring algorithm based on the edge-to-noise ratio has been applied to improve the quality of spiral CT images. Since the discrepancy measure used to quantify the edge and noise effects is not symmetric, there are several ways to formulate the edge-to-noise ratio. This article is to investigate the performance of those ratios with phantom and patient data. In the phantom study, it is shown that all the ratios share similar properties, validating the blind deblurring algorithm. The image fidelity improvement varies from 29% to 33% for different ratios, according to the root mean square error (RMSE) criterion; the optimal iteration number determined for each ratio varies from 25 to 35. Those ratios that are associated with most satisfactory performance are singled out for the image fidelity improvement of about 33% in the numerical simulation. After automatic blind deblurring with the selected ratios, the spatial resolution of CT is substantially refined in all the cases tested.
منابع مشابه
Blind deblurring of spiral CT images Based on ENR and Wiener filter
In previous studies, we developed a blind deblurring algorithm based on the edge-to-noise ratio (ENR) and EM algorithm to improve the quality of spiral CT images. In this work, we apply the Wiener filter in place of the EM algorithm to improve the timing performance. The algorithm works well in patient studies. After fully automatic blind deblurring, the conspicuity of the submillimeter feature...
متن کاملAssessment the effect of CT localizer parameter on radiation dose and image quality of GE CT spiral images, A phantom study
Introduction: Using computed tomography (CT) is increasing significantly in Iran and worldwide. Reduction of CT's radiation dose is a critical concern. The aim of this study was evaluating the effect of localizer kVp on spiral CT images when the tube current modulation (TCM) is activated. Materials and Methods: A special wedding cake phantom with circular in...
متن کاملShearlet-Based Adaptive Noise Reduction in CT Images
The noise in reconstructed slices of X-ray Computed Tomography (CT) is of unknown distribution, non-stationary, oriented and difficult to distinguish from main structural information. This requires the development of special post-processing methods based on the local statistical evaluation of the noise component. This paper presents an adaptive method of reducing noise in CT images employing th...
متن کاملBlind Deconvolution with Canny Edge Detection: an Efficient Method for Deblurring
This paper tries to understand the study of Restored Motion Blurred Images by using four types of deblurring methods: Regularized filter, Wiener filter, Lucy Richardson and Blind Image Deconvolution. There are some indirect restoration techniques like Regularized filtering, Weiner filtering, LR Filtering in which restoration results are obtained after number of iterations. The problem of such m...
متن کاملComparative Study and Qualitative-Quantitative Investigations of Several Motion Deblurring Algorithms
Motion blur caused by relative motion between the camera and the object being captured is an everyday situation that deteriorates the quality of the images largely. Even a photograph captured in low light conditions or that of a fast moving object undergo motion blur and cause significant degradation of the image and demands for deblurring the same to reconstruct the original image. The paper a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 29 5 شماره
صفحات -
تاریخ انتشار 2002