Validity of using multi-frequency bioelectrical impedance analysis to measure skeletal muscle mass in preschool children

نویسندگان

  • Kanako Fujii
  • Akiko Ishizaki
  • Ayano Ogawa
  • Takuya Asami
  • Hyosong Kwon
  • Akinobu Tanaka
  • Noboru Sekiya
  • Shouji Hironaka
چکیده

[Purposes] Although it is recommended to develop a habit of physical activities, there is no easy way to measure skeletal muscle mass in preschool children, which cause the difficulty of evaluation. The purpose of this study was to examine the validity of body composition including the skeletal muscle mass assessment using multi-frequency bioelectrical impedance analysis by comparing body fat mass obtained by using multi-frequency bioelectrical impedance analysis method and body mass index formulas. [Subjects and Methods] Ninety-four children were surveyed for age, height, weight, grip strength, maximum occlusal force, thickness of muscle and fat mass (masseter and lower limb), body fat mass, skeletal muscle mass, and calf circumference. We assessed additional parameters, which were thought to be related to skeletal muscle mass, to ensure validity. [Results] A strong correlation was found in body fat mass values obtained using the multi-frequency bioelectrical impedance analysis method and those obtained using the body mass index formulas. Additionally, strong correlation coefficients were found between the skeletal muscle mass/height obtained using the multi-frequency bioelectrical impedance analysis method and grip strength and calf circumference. [Conclusion] Our results indicate that skeletal muscle mass can be reliably measured using the multi-frequency bioelectrical impedance analysis method in preschool children.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Muscle Mass, Total Body Water and Total Body Protein in Type II Diabetics with Healthy Matched Adults by Bioelectrical Impedance Analysis

Background: Bioelectrical impedance analysis (BIA) is a new and rapid technique to validate body composition. Several studies have used this technique to evaluate body compositions, such as muscle mass, in diabetic patients, but the results are very different. This may due the differences between diabetic patients and control group. Therefore, this study aimed to compare the muscle mass of diab...

متن کامل

The Performance of Five Bioelectrical Impedance Analysis Prediction Equations against Dual X-ray Absorptiometry in Estimating Appendicular Skeletal Muscle Mass in an Adult Australian Population

Appendicular skeletal muscle mass (ASM) is a diagnostic criterion for sarcopenia. Bioelectrical impedance analysis (BIA) offers a bedside approach to measure ASM but the performance of BIA prediction equations (PE) varies with ethnicities and body composition. We aim to validate the performance of five PEs in estimating ASM against estimation by dual-energy X-ray absorptiometry (DXA). We recrui...

متن کامل

Comparison of single- or multifrequency bioelectrical impedance analysis and spectroscopy for assessment of appendicular skeletal muscle in the elderly.

Bioelectrical impedance analysis (BIA) is used to assess skeletal muscle mass, although its application in the elderly has not been fully established. Several BIA modalities are available: single-frequency BIA (SFBIA), multifrequency BIA (MFBIA), and bioelectrical impedance spectroscopy (BIS). The aim of this study was to examine the difference between SFBIA, MFBIA, and BIS for assessment of ap...

متن کامل

A Multi-Stage Ultra-Endurance Run over 1,200 KM Leads to a Continuous Accumulation of Total Body Water.

We determined whether ultra-runners in a multi-stage ultra- endurance run lose body mass, fat mass, skeletal muscle mass or total body water in a descriptive field study at the 'Deutschlandlauf' 2007 a 1,200 km run within 17 consecutive days with 10 male non-professional Caucasian ultra-runners (mean ± SD, 43.8 ± 6.2 years, 73.8 ± 6.0 kg body mass, 1.77 ± 0.05 m body height, BMI 23.3 ± 1.8 kg·m...

متن کامل

Phase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis

Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2017