Target volume coronary MRA revisited: usefulness of non-rigid reregistration of multi-frame 3D MRA acquisitions at 3T

نویسندگان

  • Masaki Ishida
  • Shinichi Takase
  • Ryohei Nakayama
  • Katsuhiro Inoue
  • Yoshitaka Goto
  • Yasutaka Ichikawa
  • Kakuya Kitagawa
  • Hajime Sakuma
چکیده

Background Free-breathing whole-heart coronary MR angiography (MRA) is an established method that can visualize all coronary arteries within a single acquisition. However, a long acquisition time and suboptimal arterial signal due to thick SLAB are major limitations of 3T gradient-echo whole-heart coronary MRA without contrast. Alternatively, target-volume coronary MRA can be used to visualize coronary arteries within a predefined target volume within a shorter acquisition time. In addition, relatively small SLAB volume of this approach permits acquisitions of multi-frame 3D data without prolonging scan duration. Recently, non-rigid image registration has been emerged as a technique which can merge images and improve SNR and CNR. The purpose of this study was to develop a new technique to obtain high quality free-breathing target-volume coronary MRA with shorter acquisition time by employing multi-frame 3D acquisitions and non-rigid image registration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3T Coronary MRA using 3D Multi-interleaved Multi-echo Acquisition and VARPRO Fat-water Separation

Introduction: Coronary MR Angiography is a valuable tool for non-invasive assessment of coronary arteries. Presently, contrastenhanced, fat-saturated, ECG-triggered and navigator-gated 3D spoiled gradient-echo sequence is employed for whole-heart Coronary MRA at 3T. However, large static field variations at 3T frequently result in non-uniform fat-suppression over the field-of-view (FOV), obscur...

متن کامل

Can 3T MR angiography replace DSA for the identification of arteries feeding intracranial meningiomas?

BACKGROUND AND PURPOSE For identifying the arterial feeders of meningiomas, the usefulness of 3D TOF MRA at 3T has not been systematically investigated. This study was intended to assess whether unenhanced 3D TOF MRA at 3T can replace DSA for the identification of arteries feeding intracranial meningiomas and whether it is useful for assessing their dural attachment. MATERIALS AND METHODS Twe...

متن کامل

Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography.

OBJECTIVES The goal of the present study was to develop a strategy for three-dimensional (3D) volume acquisition along the major axes of the coronary arteries. BACKGROUND For high-resolution 3D free-breathing coronary magnetic resonance angiography (MRA), coverage of the coronary artery tree may be limited due to excessive measurement times associated with large volume acquisitions. Planning ...

متن کامل

Follow-up of coiled cerebral aneurysms at 3T: comparison of 3D time-of-flight MR angiography and contrast-enhanced MR angiography.

BACKGROUND AND PURPOSE Our aim was to compare contrast-enhanced MR angiography (CE-MRA) and 3D time-of-flight (TOF) MRA at 3T for follow-up of coiled cerebral aneurysms. MATERIALS AND METHODS Fifty-two patients treated with Guglielmi detachable coils for 54 cerebral aneurysms were evaluated at 3T MRA. 3D TOF MRA (TR/TE = 23/3.5; SENSE factor = 2.5) and CE-MRA by using a 3D ultrafast gradient-...

متن کامل

The clinical utility of contrast enhanced whole-heart coronary MRA with 32-channel coil at 3T scanner in the era of 64 and more-slice CT

Background Sixty-four and more-slice cardiac CT provides rapid and high quality coronary CT angiography for the majority of clinical needs of non-invasive evaluation of coronary artery. However, the recent advance of whole-heart coronary MRA has been able to provide high-quality of coronary MRA and also myocardial image in a reasonable scan time. The purpose of this study was to evaluate the cl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015