Identification of Neisseria spp., Haemophilus spp., and other fastidious gram-negative bacteria with the MicroScan Haemophilus-Neisseria identification panel.

نویسندگان

  • W M Janda
  • J J Bradna
  • P Ruther
چکیده

The Haemophilus-Neisseria identification (HNID) panel (American MicroScan, Sacramento, Calif.) is a 4-h microdilution format system for identification of Haemophilus and Neisseria spp., Branhamella (Moraxella) catarrhalis, and Gardnerella vaginalis. The HNID panel was evaluated by using 423 clinical isolates and stock strains of these organisms, and HNID identifications were compared with those obtained by conventional methods. In addition, 32 isolates representing six genera not included in the HNID data base were tested to determine whether these organisms would produce unique biotype numbers for possible inclusion in the data base. The HNID panel correctly identified 95.3% of 86 Neisseria gonorrhoeae strains, 96% of 25 G. vaginalis strains, and 100% of 28 Neisseria lactamica strains and 48 B. catarrhalis strains. Only 64.7% of 68 Neisseria meningitidis isolates were identified correctly owing to false-negative or equivocal carbohydrate and/or aminopeptidase reactions. Among the Haemophilus spp., 98.8% of 83 H. influenzae strains, 97.1% of 34 H. parainfluenzae strains, and 80% of 15 H. aphrophilus and H. paraphrophilus strains were correctly identified. Eight strains of Neisseria cinerea, a species not included in the data base, produced profiles identical with those for B. catarrhalis and N. gonorrhoeae. Isolates of other species not included in the data base, including Eikenella corrodens, Kingella spp., and Cardiobacterium hominis, produced unique biochemical reaction patterns on the panel. Modification of interpretative criteria for certain tests, expansion of the data base to include other species, and suggestions for additional confirmatory tests will increase the accuracy and utility of the HNID panel.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical evaluation of the Vitek Neisseria-Haemophilus Identification card.

A clinical evaluation of the Vitek Neisseria-Haemophilus Identification (NHI) card (Vitek Systems, Inc., Hazelwood, Mo.) was performed with 480 clinical isolates and stock strains of Neisseria spp., Haemophilus spp., and other fastidious microorganisms included in the data base of the system. Identifications obtained with the NHI card were compared with those determined by conventional methods....

متن کامل

Multicenter evaluation of the new Vitek 2 Neisseria-Haemophilus identification card.

The new Neisseria-Haemophilus identification (NH) card for Vitek 2 was compared with 16S rRNA gene sequencing (16S) as the reference method for accurate identification of Neisseria spp., Haemophilus spp., and other fastidious gram-negative bacteria. Testing was performed on the Vitek 2 XL system with modified software at three clinical trial laboratories. Reproducibility was determined with nin...

متن کامل

Assessment of the nasopharyngeal bacterial flora of rhesus macaques: moraxella, Neisseria, haemophilus, and other genera.

The nasopharyngeal bacterial flora of healthy rhesus macaques was surveyed for the presence of Neisseria and Haemophilus species, as well as Moraxella catarrhalis. M. catarrhalis was found both in healthy rhesus macaques and in possibly immunocompromised rhesus macaques. Several Haemophilus spp. that are part of the normal nasopharyngeal bacterial flora of humans were found in many animals; the...

متن کامل

Recommendations for susceptibility tests on fastidious organisms and those requiring special handling.

Fastidious organisms present problems in antimicrobial susceptibility testing related to particular cultural requirements or slow growth. Methods for commonly isolated fastidious organisms, including haemolytic streptococci, Neisseria spp. and Haemophilus spp., are included in the description of the standardized disc diffusion method. However, some further information is given here for Haemophi...

متن کامل

Development of a test system for rapid differentiation of Neisseria and Haemophilus spp.

A qualitative micromethod (IDS Rapid NH system) employing conventional and single-substrate enzyme tests was developed for the biochemical characterization of Neisseria spp., Haemophilus spp., and other gram-negative species. A total of over 140 dehydrated, miniaturized biochemical tests were investigated for their ability to distinguish species. Computer-assisted test selection and pair separa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 27 5  شماره 

صفحات  -

تاریخ انتشار 1989