Analysis and correction of pressure wave distortion in fluid-filled catheter systems.
نویسندگان
چکیده
Dvnamic characteristics of a variety of catheters and their dependence on various operating parameters are presented. Careful flushing of the catheter with degassed water or saline considerably improves the performance of these systems. The operating temperature, number of catheter uses, and average transmural pressure difference do not have a significant effect. The error due to catheter distortion in commonly used left ventricular performance indices (end diastolic pressure, peak systolic pressure, maximum dp/dt and Vma,) was assessed. On the basis of these results, it is shown that the natural frequency of the catheter system must be greater than 40 Hz to produce results accurate to 10%. The experimental data were used to develop a semi-empirical model for the catheter transducer system. This model was used in the design of an analog compensator to further improve the dynamic characteristics of the catheter transducer system. The compensator requires only two parameter settings, catheter natural frequency and damping ratio.
منابع مشابه
Frequency Analysis of Catheter Systems Used for Invasive Blood Pressure Monitoring
The resonant behavior of fluid-filled catheter manometers can produce severe distortion in the monitored blood pressure waveform. Although gradual improvements in components has resulted in catheter systems having adequate frequency response for human blood pressure measurement, these systems are frequently compromised by the presence of occult air bubbles in the fluid column. A general model w...
متن کاملLimitation of correction of frequency dependent artefact in pressure recordings using harmonic analysis.
Frequency dependent phase and amplitude distortion may theoretically be minimized using correction formulae derived from a model which assumes that water-filled catheter-manometer systems are analogous to an oscillating mass attached to a spring and damping pot. This study defines the practical limits of this correction technique using harmonic analysis of simultaneously recorded water-filled a...
متن کاملاستفاده از روش SPH برای مدلسازی Sloshing در یک مخزن نیمه پر
The motion of fluids within partially filled containers has been the subject of much study by scientists and engineers due, in large part, to its importance in many practical applications. For example, civil engineers and seismologists have actively studied the effects of earthquake-induced fluid motions on oil tanks and water towers. In recent years, aerospace engineers have been concerned wit...
متن کاملSound Wave Propagation in Viscous Liquid-Filled Non-Rigid Carbon Nanotube with Finite Length
In this paper, numerical results obtained and explained from an exact formula in relation to sound pressure load due to the presence of liquid inside the finite-length non-rigid carbon nanotubes (CNTs), which is coupled with the dynamic equations of motion for the CNT. To demonstrate the accuracy of this work, the obtained formula has been compared to what has been used by other research...
متن کاملWave Motion and Stop-Bands in Pipes with Helical Characteristics Using Wave Finite Element Analysis
Pipes are widely used in many industrial and mechanical applications and devices. Although there are many different constructions according to the specific application and device, these can show helical pattern, such as spiral pipes, wire-reinforced pipes/shells, spring-suspension, and so on. Theoretical modelling of wave propagation provides a prediction about the dynamic behavior, and it is f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 49 1 شماره
صفحات -
تاریخ انتشار 1974