Dynamic contrast enhancement patterns of solitary pulmonary nodules on 3D gradient-recalled echo MRI.
نویسندگان
چکیده
OBJECTIVE The purpose of this study was to determine whether contrast enhancement features on 3D volumetric gradient-recalled echoMR images allow differentiation of benign from malignant solitary pulmonary nodules. MATERIALS AND METHODS Forty patients with solitary pulmonary nodules (range of greatest diameter, 7-40 mm) detected on CT underwent unenhanced MRI and contrast-enhanced MRI performed in 10 consecutive dynamic 3D volumetric gradient-recalled echo sequences every 30 seconds. Contrast enhancement patterns (homogeneous, heterogeneous, rim, peripheral, and central) of the lesions were visually evaluated, and time-intensity curves of the lesions were drawn. RESULTS Twenty patients had benign lesions (nine, tuberculoma; one, aspergilloma; nine, round atelectasis; one, postinflammatory nodule). The other 20 patients had malignant lesions (18, primary lung cancer; two, metastasis). At visual analysis, all 20 malignant lesions displayed peripheral enhancement with progressive heterogeneous fill-in on the late images. All nine tuberculomas and the aspergilloma had rim enhancement, and all nine round atelectasis lesions and the postinflammatory nodule had early intense homogeneous enhancement. Regarding the time-intensity curves, all malignant lesions except one lung cancer lesion had early peak enhancement with rapid washout. All benign lesions displayed early increasing enhancement with an early plateau in the second minute after contrast administration (nine tuberculomas and one aspergilloma) or a late plateau in the fourth minute (nine round atelectasis lesions and one postinflammatory nodule). CONCLUSION Rim contrast enhancement is highly valuable in the diagnosis of tuberculoma. Time-intensity curve types can be taken into consideration for noninvasive differentiation of lung cancer, tuberculoma, and round atelectasis.
منابع مشابه
Solitary pulmonary nodules: dynamic contrast-enhanced MR imaging--perfusion differences in malignant and benign lesions.
PURPOSE To determine whether dynamic contrast material-enhanced magnetic resonance (MR) imaging with use of kinetic and morphologic parameters reveals statistically significant differences between malignant and benign solitary pulmonary nodules. MATERIALS AND METHODS Fifty-eight patients met the inclusion criteria of a solitary 5-40-mm pulmonary nodule without calcification or fat at computed...
متن کاملMS lesions are better detected with 3D T1 gradient-echo than with 2D T1 spin-echo gadolinium-enhanced imaging at 3T.
BACKGROUND AND PURPOSE In multiple sclerosis, gadolinium enhancement is used to classify lesions as active. Regarding the need for a standardized and accurate method for detection of multiple sclerosis activity, we compared 2D-spin-echo with 3D-gradient-echo T1WI for the detection of gadolinium-enhancing MS lesions. MATERIALS AND METHODS Fifty-eight patients with MS were prospectively imaged ...
متن کاملUltra high spatio-temporal resolution hepatic MRI using a novel 2-point Dixon time resolved 3D SPGR sequence at 3T
Introduction: Dynamic contrast enhanced MRI (DCEMRI) is commonly used in abdominal-pelvic imaging for detection and characterization of primary and metastatic lesions. Current methods have adequate spatial resolution but the temporal resolution is often insufficient for visualization of hypervascular tumors. Optimal timing of the contrast arrival and robust fat suppression are the two critical ...
متن کاملDifferentiation between malignant and benign solitary pulmonary nodules with proton density weighted and ECG-gated magnetic resonance imaging.
OBJECTIVE To estimate performance of MRI for differentiating malignant from benign solitary pulmonary nodules (SPN) using morphological characteristics. MATERIAL AND METHODS MRI in 46 patients with SPN (mean diameter: 19 mm) was carried out on 1.0 Tesla scanner using ECG-gated, gradient echo sequence. Morphological signs of SPN were determined and compared with previously performed helical-CT...
متن کاملDifference in enhancement between spin echo and 3-dimensional fast spoiled gradient recalled acquisition in steady state magnetic resonance imaging of brain metastasis at 3-T magnetic resonance imaging.
OBJECTIVE To compare the enhancement of brain metastasis between 3-dimensional fast spoiled gradient recalled acquisition in the steady state (3DFSPGR) and spin echo (SE) T1-weighted imaging at 3-T magnetic resonance imaging. METHODS The subjects comprised 18 patients with 81 suspected brain metastases. Axial SE and 3DFSPGR images were obtained before and after gadoteridol injection. The sign...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJR. American journal of roentgenology
دوره 189 6 شماره
صفحات -
تاریخ انتشار 2007