Label-free detection of DNA using novel organic-based electrolyte-insulator-semiconductor.

نویسندگان

  • Tsung-Wu Lin
  • Dhananjay Kekuda
  • Chih-Wei Chu
چکیده

In this study, we have constructed the first organic field effect sensor based on an electrolyte-insulator-semiconductor structure (OEIS) and applied this novel device to pH and DNA sensing. Variations in the insulator-electrolyte surface potential, which originate from either the change of the ionization states of the insulator surface groups or the binding of charged molecules to the insulator surface, modify the flat band voltage (V(FB)) of the OEIS sensor. The pH sensing experiments of OEIS sensor showed that the output signal linearly depended on pH solution in the range from pH 2 to pH 12, and an average sensitivity of 44.1 mV/pH was obtained. In the biosensing experiments, the absorption of positively charged poly-L-lysine on the insulator surface resulted in the reduction of the V(FB) value, whereas the subsequent binding of negatively charged single-stranded DNA probe (ssDNA) via electrostatic interaction increased the V(FB) value. Furthermore, the ssDNA-immobilized OEIS device was successfully used for the detection of DNA hybridization. The detection limit of complementary DNA was as low as 1 microM, and the output signal of OEIS biosensor linearly increased with the logarithm of complementary DNA concentration in the range from 5x10(-5) to 10(-7) M. The easy and inexpensive fabrication of the OEIS device allows to be served as a potentially disposable and sensitive biosensor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel label-free cocaine assay based on aptamer-wrapped single-walled carbon nanotubes

Objective(s): This paper describes a selective and sensitive biosensor based on the dissolution and aggregation of aptamer wrapped single-walled carbon nanotubes. We report on the direct detection of aptamer–cocaine interactions, namely between a DNA aptamer and cocaine molecules based on near-infrared absorption at λ807. Materials and Methods: First a DNA aptamer recognizing cocaine was non-co...

متن کامل

Linköping Studies in Science and Technology

The discovery of semi-conducting and conducting organic materials has opened new possibilities for electronic devices and systems. Applications, previously unattainable for conventional electronics, have become possible thanks to the development of conjugated polymers. Conjugated polymers that are both ionand electron conducting, allow for electrochemical doping and de-doping via reversible pro...

متن کامل

Electrolyte – Semiconductor Combinations for Organic Electronic Devices

The discovery of semi-conducting organic materials has opened new possibilities for electronic devices and systems because of their solution processibility, lightweight and flexibility compared to inorganic semiconductors. The combination of semiconductors with electrolytes, and more especially organic semiconductors and solid electrolytes has attracted the attention of researchers because of t...

متن کامل

Label-Free Immunodetection in High Ionic Strength Solutions Using Carbon Nanotube Transistors with Nanobody Receptors

Nanomaterial-based field-effect transistors (FETs) have been proposed for real-time, label-free detection of various biological species. However, screening of the analyte charge by electrolyte ions (Debye screening) has so far limited their use in physiological samples. Here, this challenge is overcome by combining FETs based on single-walled semiconducting carbon nanotube networks (SWCNTs) wit...

متن کامل

Designing a Label Free Aptasensor for Detection of Methamphetamine

A label-free electrochemical nucleic acid aptasensor for the detection of methamphetamine (MA) by the immobilization of thiolated self-assembled DNA sequences on a gold nanoparticles-chitosan modified electrode is constructed. When MA was complexed specifically to the aptamer, the configuration of the nucleic acid aptamer switched to a locked structure and the interface of the biosensor changed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 25 12  شماره 

صفحات  -

تاریخ انتشار 2010