Improving signal-to-noise ratio in transcranial magnetic resonance guided focused ultrasound
نویسندگان
چکیده
Background/introduction Signal-to-Noise Ratio (SNR) can be increased in Magnetic Resonance Imaging (MRI) using Radio Frequency (RF) coils. Of all the options for increasing SNR, coils provide the greatest gains for the dollars spent. Coils for 1.5 and 3 Tesla MRI systems consist of conductive loops that are tuned to resonate at the fundamental frequency associated with the field strength of the MRI scanner. These coils are the transducers between the MR signal and the system electronics and are sensitive to the magnetic fields of the MR signal via Faraday’s Law of Maxwell’s equations. Sensitivity of a coil to the signal in the imaging sample depends primarily on the geometry and position of the loop with respect to the sample. To achieve the highest SNR requires the coil to be in close proximity to the sample of interest, small enough that it is not sensitive to regions outside the region of interest and large enough to pick up the signal at the depth of interest. Other factors such as dielectric or conductive material loading of the coils can significantly affect the tuning and function of a coil. Custom coils designed for a specific application typically provide much higher SNR than commercial coils that are designed for general purpose imaging of a broad range body habitus. Coils that provide even small gains in SNR provide significant imaging improvement. For example, a specific-purpose (SP) coil that can provide a 40% SNR improvement over a general-purpose (GP) coil, can achieve the same image quality as the GP coil in half the imaging time. Similarly, an SP coil that can provide a factor of 2 improvement in SNR over a GP coil can achieve the same image quality 4 times faster than the GP coil. SNR can be used to improve image quality, temporal and spatial resolution, and enable or improve imaging functionality such as temperature measurement accuracy, Diffusion Tensor Imaging (DTI), and MR Acoustic Radiation Force Imaging (MR-ARFI).
منابع مشابه
PET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors
Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...
متن کاملOptimization of a four-coil array arrangement for brain therapy by MR-guided transcranial focused ultrasounds
A particularly critical issue for brain therapy with transcranial high-power focused ultrasound (HIFU) is to optimize the accuracy and rapidity of the temperature follow-up during the heating. MRI is a well-suited candidate for temperature monitoring since it offers several parameters such as the proton resonance frequency shift. Up-to-now, temperature scans were achieved using the standard bod...
متن کاملRapid MR-ARFI method for focal spot localization during focused ultrasound therapy.
MR-guided focused ultrasound (FUS) is a noninvasive therapy for treating various pathologies. MR-based acoustic radiation force imaging (MR-ARFI) measures tissue displacement in the focal spot due to acoustic radiation force. MR-ARFI also provides feedback for adaptive focusing algorithms that could correct for phase aberrations caused by the skull during brain treatments. This work developed a...
متن کاملTranscranial magnetic resonance imaging- guided focused ultrasound surgery of brain tumors: initial findings in 3 patients.
OBJECTIVE This work evaluated the clinical feasibility of transcranial magnetic resonance imaging-guided focused ultrasound surgery. METHODS Transcranial magnetic resonance imaging-guided focused ultrasound surgery offers a potential noninvasive alternative to surgical resection. The method combines a hemispherical phased-array transducer and patient-specific treatment planning based on acous...
متن کاملThree-axis MR-conditional robot for high-intensity focused ultrasound for treating prostate diseases transrectally
BACKGROUND A prototype magnetic resonance image (MRI)-conditional robot was developed for navigating a high-intensity focused ultrasound (HIFU) system in order to treat prostate cancer transrectally. MATERIALS AND METHODS The developed robotic device utilizes three PC-controlled axes: a linear axis for motion along the rectum, an angular axis for rotation in the rectum, and a linear axis to l...