The relationship between central visual field sensitivity and macular ganglion cell/inner plexiform layer thickness in glaucoma.

نویسندگان

  • Ji-Woong Lee
  • Esteban Morales
  • Farideh Sharifipour
  • Navid Amini
  • Fei Yu
  • Abdelmonem A Afifi
  • Anne L Coleman
  • Joseph Caprioli
  • Kouros Nouri-Mahdavi
چکیده

AIMS To explore the correlation of local macular ganglion cell/inner plexiform layer (GC/IPL) thickness measurements with sensitivity at individual test locations on the central 10-2 visual fields (VFs) in patients with glaucoma. METHODS One hundred thirty-seven eyes of 125 patients with spectral domain optical coherence tomography (OCT) and 10-2 VFs were included. The exported thickness matrices (200×200) of GC/IPL measurements were centred on the fovea. Total deviation values at each test location were correlated with the 20 000 GC/IPL thickness measurements in the corresponding inferior or superior hemiretina, and areas of highest correlation were plotted. Macular structure-function relationships were also examined between six wedge-shaped GC/IPL sectors and the corresponding VF clusters. A multivariate model was built to identify the 10-2 VF test locations associated with each GC/IPL sector thickness. RESULTS Average mean deviation on 10-2 VFs was -9.2±6.1 dB. The 10-2 VF test points demonstrated correlations with GC/IPL thickness in localised arcuate patterns mostly limited within the central 4.8×4.0 mm measurement ellipse (ρ=0.43-0.74, p<0.05 for all). Twenty-one test points of the 10-2 VF were the best predictors of sectoral GC/IPL thickness. Sectoral VF-OCT correlations were high (ρ=0.53-0.66, p<0.001) and did not significantly change after adjusting for retinal GC displacement (p>0.05). CONCLUSIONS Macular OCT/VF relationships have localised arcuate characteristics in the central region of the macula. Given the overlapping nature of structure-function relationships, a smaller number of VF test locations may be used to summarise macular functional damage. TRIAL REGISTRATION NUMBER NCT01742819.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differences in Relationship Between Macular Inner Retinal Layer Thickness and Retinal Sensitivity in Eyes With Early and Progressed Glaucoma.

PURPOSE To determine if the relationship between retinal sensitivity and macular inner retinal layer thickness differs between primary open-angle glaucoma (POAG) with mild and advanced central visual field (VF) damage. METHODS One eye of 153 POAG patients was included. Using spectral-domain optical coherence tomography, we measured the average thickness of the macular ganglion cell-inner plex...

متن کامل

The association between photoreceptor layer thickness measured by optical coherence tomography and visual sensitivity in glaucomatous eyes

PURPOSE To assess the thickness of the photoreceptor layer in the macular region in glaucomatous eyes. METHOD Humphrey 10-2 visual field (VF) testing was carried out and mean threshold (mTH) was calculated in 118 eyes from 118 patients with open angle glaucoma. Macular optical coherence tomography (OCT) measurements (RS 3000, Nidek Co.ltd., Aichi, Japan) were also carried out in all eyes. Thi...

متن کامل

Measurement of macular structure-function relationships using spectral domain-optical coherence tomography (SD-OCT) and pattern electroretinograms (PERG)

BACKGROUND Retinal ganglion cell (RGC) death is a common cause of loss of vision during glaucoma. Pattern electroretinogram (PERG) is an objective measure of the central retinal function that correlates with macular GCL thickness. The aim of this study is to determine possible relationships between the N95 amplitude of pattern electroretinogram (PERGamp) and macular ganglion cell/inner plexifor...

متن کامل

Comparison of Macular Integrity Assessment (MAIA ™), MP-3, and the Humphrey Field Analyzer in the Evaluation of the Relationship between the Structure and Function of the Macula

PURPOSE This study was conducted in order to compare relationships between the macular visual field (VF) mean sensitivity measured by MAIATM (Macular Integrity Assessment), MP-3, or Humphry field analyzer (HFA) and the ganglion cell and inner plexiform layer (GCA) thicknesses. METHODS This cross-sectional study examined 73 glaucoma patients and 19 normal subjects. All subjects underwent measu...

متن کامل

Segmented inner plexiform layer thickness as a potential biomarker to evaluate open-angle glaucoma: Dendritic degeneration of retinal ganglion cell

PURPOSE To evaluate the changes of retinal nerve fiber layer (RNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), and ganglion cell-inner plexiform layer (GCIPL) thicknesses and compare structure-function relationships of 4 retinal layers using spectral-domain optical coherence tomography (SD-OCT) in macular region of glaucoma patients. METHODS In cross-sectional study, a total of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 101 8  شماره 

صفحات  -