Replacement of a Photomultiplier Tube in a 2-inch Thallium-doped Sodium Iodide Gamma Spectrometer with Silicon Photomultipliers and a Light Guide

نویسندگان

  • CHANKYU KIM
  • HYOUNGTAEK KIM
  • JONGYUL KIM
  • CHAEHUN LEE
  • HYUNJUN YOO
  • DONG UK KANG
  • MINSIK CHO
  • MYUNG SOO KIM
  • DAEHEE LEE
  • YEWON KIM
  • KYUNG TAEK LIM
  • SHIYOUNG YANG
چکیده

The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) 20 20 scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV. Copyright © 2015, Published by Elsevier Korea LLC on behalf of Korean Nuclear Society. ). d under the terms of the Creative Commons Attribution Non-Commercial License (http:// ich permits unrestricted non-commercial use, distribution, and reproduction in any mecited. sevier Korea LLC on behalf of Korean Nuclear Society. Fig. 1 e Schematic comparison of the general gamma spectrometer (based on the vacuum photomultiplier tube), and the proposed gamma spectrometer using a light guide and silicon photomultipliers. NaI(Tl), thallium-doped sodium iodide. Nu c l E n g T e c h n o l 4 7 ( 2 0 1 5 ) 4 7 9e4 8 7 480

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Next Generation of Photo-Detectors for Particle Astrophysics

We advocate support of research aimed at developing alternatives to the photomultiplier tube for photon detection in large astroparticle experiments such as gamma-ray and neutrino astronomy, and direct dark matter detectors. Specifically, we discuss the development of large area photocathode microchannel plate photomultipliers and silicon photomultipliers. Both technologies have the potential t...

متن کامل

Single Photon Imaging and Instrumentation

Abbreviations 2D, 3D 2-dimensional, 3-dimensional CZT cadmium zinc telluride EKG electric signal from the heart FBP filtered backprojection FOV field-of-view GE General Electric Ge(Li) germanium detector doped with lithium MLEM maximum likelihood expectation maximization NaI(Tl) sodium iodine doped with thallium NM nuclear medicine OSEM ordered subset expectation maximization PET positron emiss...

متن کامل

Photon Detection with Silicon Photomultipliers

The Silicon Photomultiplier (SPM) addresses the challenge of detecting, timing and quantifying low-light signals down to the single-photon level. Traditionally the province of the Photomultiplier Tube (PMT), Avalanche Photodiode (APD), or PIN photodiode with high-gain amplifier, the Silicon Photomultiplier now offers a highly attractive alternative that closely mimics the low light detection ca...

متن کامل

Performance of Silicon Photomultipliers in photon number and time resolution

Silicon Photomultipliers (SiPMs) are a novel generation of photon detectors designed as an array of independently operated Geiger-mode APDs (pixels) with common output. SiPM provides proportional detection of low-level light pulses starting from single photons with remarkable photon number and time resolution at room temperature. Now they are worldwide recognized to be competitive with vacuum p...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015