Ion recombination in liquid ionization chambers Development of an experimental method to quantify general recombination

نویسنده

  • Jonas Andersson
چکیده

An experimental method (the two-dose-rate method) for the correction of general recombination losses in liquid ionization chambers has been developed and employed in experiments with different liquids and radiation qualities. The method is based on a disassociation of initial and general recombination, since an ionized liquid is simultaneously affected by both of these processes. The two-dose-rate method has been compared to an existing method for general recombination correction for liquid ionization chambers, and has been found to be the most robust method presently available. The soundness of modelling general recombination in liquids on existing theory for gases has been evaluated, and experiments indicate that the process of general recombination is similar in a gas and a liquid. It is thus reasonable to employ theory for gases in the two-dose-rate method to achieve experimental corrections for general recombination in liquids. There are uncertainties in the disassociation of initial and general recombination in the two-dose-rate method for low applied voltages, where initial recombination has been found to cause deviating results for different liquids and radiation qualities. Sensitivity to ambient electric fields has been identified in the microLion liquid ionization chamber (PTW, Germany). Experimental data may thus be perturbed if measurements are conducted in the presence of ambient electric fields, and the sensitivity has been found to increase with an increase in the applied voltage. This can prove to be experimentally limiting since general recombination may be too severe for accurate corrections if the applied voltage is low.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On the property of measurements with the PTW microLion chamber in continuous beams.

PURPOSE The performance of liquid ionization chambers, which may prove to be useful tools in the field of radiation dosimetry, is based on several chamber and liquid specific characteristics. The present work investigates the performance of the PTW microLion liquid ionization chamber with respect to recombination losses and perturbations from ambient electric fields at various dose rates in con...

متن کامل

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator

Most modern radiation therapy devices allow the use of very small fields, either through beamlets in Intensity-Modulated Radiation Therapy (IMRT) or via stereotactic radiotherapy where positioning accuracy allows delivering very high doses per fraction in a small volume of the patient. Dosimetric measurements on medical accelerators are conventionally realized using air-filled ionization chambe...

متن کامل

Initial recombination of ions in ionization chambers filled with hydrocarbon gases

Ion recombination in ionization chambers is usually considered as a side effect, which influences the accuracy of the determination of the absorbed dose. This is generally true for volume recombination, but not always for initial recombination, i.e. the recombination which occurs between the ions created in the same track of a single ionizing particle or resulting from a single ionization event...

متن کامل

Measurement of ion recombination correction factors for plane parallel ionization chambers

The work presented focuses on the measurement of Ja e plots and determination of ion recombination factors for plane parallel ionisation chambers used in pulsed electron beams. The ability to measure the Ja e plots accurately is useful when commisioning a new chamber and the ion recombination correction factor needs to be known when the chamber is calibrated in a beam quality di erent from the ...

متن کامل

Correction for Recombination Loss of Ions in Ionization Chambers - Nuclear Science Symposium, 1998. Conference Record. 1998 IEEE

The signal charge loss due to initial recombination and that due to volume recombination have been measured separately using parallel plate ionization chambers irradiated with cobalt60 gamma rays, over a wide range of applied voltage and air humidity. It is shown that both initial and volume recombination depend on the electric field strength and also on humidity through ion clustering reaction...