Modeling, Stability Analysis, and Testing of a Hybrid Docking Simulator

نویسندگان

  • M. Zebenaya
  • Toralf Boge
  • D. Choukroun
چکیده

A hybrid docking simulator is a hardware-in-the-loop (HIL) simulator that includes a hardware element within a numerical simulation loop. One of the goals of performing a HIL simulation at the European Proximity Operation Simulator (EPOS) is the verification and validation of the docking phase in an on-orbit servicing mission. A key feature of the HIL docking simulator setup is a feedback loop that is closed on the real force sensed at the docking interface during the contact with the probe. This force signal is used as input to the numerical simulation of the free-floating bodies in contact. The resulting relative 3D trajectory serves as a position command for the two robots end-effectors holding the probe and the docking interface. The high stiffness of the robots causes the contact duration to be shorter than the time delay in the robots' dynamics. This can lead to inconsistencies in the simulation results, to instability of the closed-loop system, and eventually to damages in the HIL system. This work presents a novel mitigation strategy to the given challenge, accompanied with stability analysis and validating experiments. The high-stiffness compliance issue is addressed by combining virtual and real compliances in the software and hardware, respectively. The method is presented here for six degrees of freedom. A linear stability analysis is provided for a 2D case. Experimental results are presented for a translational linear motion and for a 3D motion. This hybrid contact dynamics model and the accompanying analysis is envisioned to provide a safe and flexible docking simulator tool. This tool shall allow reproduction of the desired impact dynamics for any stiffness and damping characteristics within a desired stability, and thus safe, domain of operation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical and experimental stability investigation of a hardware-in-the-loop satellite docking simulator

The European Proximity Operation Simulator (EPOS) of the DLR-German Aerospace Center is a robotics-based simulator that aims at validating and verifying a satellite docking phase. The generic concept features a robotics tracking system working in closed loop with a force/torque feedback signal. Inherent delays in the tracking system combined with typical high stiffness at contact challenge the ...

متن کامل

Modeling and interactions analysis of the novel antagonist agent flibanserin with 5-hydroxytryptamine 2A (5-HT2A) serotonin receptor as a HSDD treatment in premenopausal women

Flibanserin is a novel antagonist small molecule to treat the hypoactive sexual desire disorder (HSDD) in the premenopausal women. The present article is related to the structural and electronic properties study and docking analysis of the title compound with 5-hydroxytryptamine 2A (5-HT2A) serotonin receptor. To access these aims, the molecular structure of the said compound was optimized usin...

متن کامل

Three-Phase Modeling of Dynamic Kill in Gas-Condensate Well Using Advection Upstream Splitting Method Hybrid Scheme

Understanding and modeling of three-phase transient flow in gas-condensate wells play a vital role in designing and optimizing dynamic kill procedure of each well that needs to capture the discontinuities in density, geometry, and velocity of phases but also the effect of temperature on such parameters. In this study, two-phase Advection-Upstream-Splitting-Method (AUSMV) hybrid scheme is extend...

متن کامل

Large Lithium Polymer Battery Modeling for the Simulation of Hybrid Electric Vehicles Using the Equivalent Circuit Method

In the present study, a model of a large Lithium Polymer (Li-Po) battery for use in the simulation of Hybrid Electric Vehicles (HEVs) is developed. To attain this goal, an Equivalent Circuit (EC) consisting of a series resistor and two RC parallel networks is considered. The accuracy and the response time of the model for use in an HEV simulator are studied. The battery parameters identifica...

متن کامل

Soft Tissue Modeling Using ANFIS for Training Diagnosis of Breast Cancer in Haptic Simulator

Soft tissue modeling for the creation of a haptic simulator for training medical skills has been the focus of many attempts up to now. In soft tissue modeling the most important parameter considered is its being real-time, as well as its accuracy and sensitivity. In this paper, ANFIS approach is used to present a nonlinear model for soft tissue. The required data for training the neuro-fuzzy mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • CoRR

دوره abs/1409.0562  شماره 

صفحات  -

تاریخ انتشار 2014