Quality-assured measurements of animal building emissions: particulate matter concentrations.

نویسندگان

  • Albert J Heber
  • Teng-Teeh Lim
  • Ji-Qin Ni
  • Pei-Chun Tao
  • Amy M Schmidt
  • Jacek A Koziel
  • Steven J Hoff
  • Larry D Jacobson
  • Yuanhui Zhang
  • Gerald B Baughman
چکیده

Federally funded, multistate field studies were initiated in 2002 to measure emissions of particulate matter (PM) < 10 microm (PM10) and total suspended particulate (TSP), ammonia, hydrogen sulfide, carbon dioxide, methane, nonmethane hydrocarbons, and odor from swine and poultry production buildings in the United States. This paper describes the use of a continuous PM analyzer based on the tapered element oscillating microbalance (TEOM). In these studies, the TEOM was used to measure PM emissions at identical locations in paired barns. Measuring PM concentrations in swine and poultry barns, compared with measuring PM in ambient air, required more frequent maintenance of the TEOM. External screens were used to prevent rapid plugging of the insect screen in the PM10 preseparator inlet. Minute means of mass concentrations exhibited a sinusoidal pattern that followed the variation of relative humidity, indicating that mass concentration measurements were affected by water vapor condensation onto and evaporation of moisture from the TEOM filter. Filter loading increased the humidity effect, most likely because of increased water vapor adsorption capacity of added PM. In a single layer barn study, collocated TEOMs, equipped with TSP and PM10 inlets, corresponded well when placed near the inlets of exhaust fans in a layer barn. Initial data showed that average daily mean concentrations of TSP, PM10, and PM2.5 concentrations at a layer barn were 1440 +/- 182 microg/m3 (n = 2), 553 +/- 79 microg/m3 (n = 4), and 33 +/- 75 microg/m3 (n = 1), respectively. The daily mean TSP concentration (n = 1) of a swine barn sprinkled with soybean oil was 67% lower than an untreated swine barn, which had a daily mean TSP concentration of 1143 +/- 619 microg/m3. The daily mean ambient TSP concentration (n = 1) near the swine barns was 25 +/- 8 microg/m3. Concentrations of PM inside the swine barns were correlated to pig activity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality assured measurements of animal building emissions: odor concentrations.

Standard protocols for sampling and measuring odor emissions from livestock buildings are needed to guide scientists, consultants, regulators, and policy-makers. A federally funded, multistate project has conducted field studies in six states to measure emissions of odor, coarse particulate matter (PM(10)), total suspended particulates, hydrogen sulfide, ammonia, and carbon dioxide from swine a...

متن کامل

Quality assured measurements of animal building emissions: gas concentrations.

Comprehensive field studies were initiated in 2002 to measure emissions of ammonia (NH3), hydrogen sulfide (H2S), carbon dioxide (CO2), methane (CH4), nonmethane hydrocarbons (NMHC), particulate matter <10 microm in diameter, and total suspended particulate from swine and poultry production buildings in the United States. This paper focuses on the quasicontinuous gas concentration measurement a...

متن کامل

Quality Assured Measurements of Animal Building Emissions: Part 1 - Gas Concentrations

Comprehensive field studies were initiated in 2002, to measure emissions of ammonia (NH3), hydrogen sulfide (H2S), carbon dioxide (CO2), methane (CH4), non-methane hydrocarbons (NMHC), particulate matter less than 10 microns diameter (PM10), and total suspended particulates (TSP) from swine and poultry production buildings in the U.S. This paper focuses on the quasi-continuous gas concentration...

متن کامل

Pollutants Emissions of Filling Stations and Their Impact on the Air Quality (RESEARCH NOTE)

This study investigated pollutants emissions from filling stations and their impact on the air quality. Gas monitors were employed to identify the different pollutants present in the ambient air of the study areas. The results showed that the most prominent pollutants present in the ambient air are the volatile organic compounds followed by methane, then carbon monoxide. Measurements were taken...

متن کامل

Assessment of role of concrete factories in particulate matter emissions, 2015-2016, using the AQI index and zoning by GIS software (Case study: Nasr Kashan Concrete Factory)

Background: Reducing the effects of climate change and air pollution is a global priority at present. To formulate effective policies for achieving such a reduction requires a good understanding of the underlying phenomena. This study assessed the role of Nasr Kashan Factory in the emissions of particulate matter (PM). Methods: In this cross-sectional study, PM concentrations at 9 stations ins...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Air & Waste Management Association

دوره 56 12  شماره 

صفحات  -

تاریخ انتشار 2006