Severe mitral valve regurgitation due to a large ring dehiscence in ischaemic cardiomyopathy.
نویسندگان
چکیده
منابع مشابه
Mitral valve repair and redo repair for mitral regurgitation in a heart transplant recipient
A 37-year-old man with end-stage idiopathic dilated cardiomyopathy underwent an orthotopic heart transplant followed by a reoperation with mitral annuloplasty for severe mitral regurgitation. Shortly thereafter, he developed severe tricuspid regurgitation and severe recurrent mitral regurgitation due to annuloplasty ring dehiscence. The dehisced annuloplasty ring was refixated, followed by tric...
متن کاملSafety and feasibility of a novel adjustable mitral annuloplasty ring: a multicentre European experience†
OBJECTIVES Recurrent mitral regurgitation is a significant problem after mitral valve repair in patients with functional valve disease. We report the safety and feasibility of a novel adjustable mitral annuloplasty device that permits downsizing of the anterior-posterior diameter late after initial surgery. METHODS In this multicentre, non-randomized, observational register, patients with mod...
متن کاملHigh-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient
Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...
متن کاملSHORT TERM CLINICAL OUTCOME OF PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY VERSUS SURGICAL CLOSED MITRAL COMMISSUROTOMY
BaIlon mitral valvuloplasty and closed mitral valve conunissurotomy were performed in 450 and 127 patients, respectively. Also, 254 patients with severe mitral stenosis were enrolled in a prospective randomized trial comparing the two procedures. Immediately after balloon mitral valvuloplasty, mean left atrial pressure was 11.38±3.54 mmHg, transmitral valve gradient was 1.8±2 mmHg, and mit...
متن کاملImages in cardiovascular medicine: prosthetic aortic valve and conduit dehiscence with large periconduit cavity, ascending aortic aneurysm and severe mitral regurgitation.
Prosthetic aortic valve and conduit dehiscence with periconduit cavity and ascending aortic aneurysm is an uncommon complication of aortic root surgery. It is usually recognizable at echocardiography due to an abnormal position of the prosthetic valve and conduit in relation to the native aortic annulus in conjunction with an abnormal echolucent periconduit space that fills with color flow. Mit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 43 2 شماره
صفحات -
تاریخ انتشار 2013