Mechanical ventilation during laryngeal surgery: an evaluation of the Carden tube.

نویسندگان

  • C M Soder
  • J Haight
  • J L Fredrickson
  • A A Scott
چکیده

The effectiveness and safety of the Carden tube-oxygen injector system for ventilation was studied in 18 high-risk patients with obstructive airways disease during microlaryngeal surgery. Blood gas studies during operation demonstrated a mean Pao2 of 65.6 kPa (493 torr) and a mean PaCO2 of 4.5 kPa (34 torr) during mechanical ventilation. No serious complications were noted during operation. Fifty per cent of the patients had postoperative hypercapnia and in two the trachea was re-intubated. Airway maintenance and ventilation are discussed in detail and it is concluded that the Carden tube-oxygen injector system is a safe and convenient method for ventilating the lungs of patients with pulmonary disease who require microlaryngeal surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An evaluation of the Laryngeal Tube during general anesthesia using mechanical ventilation.

UNLABELLED The Laryngeal Tube is a new supraglottic ventilatory device for airway management. It has been developed to secure a patent airway during either spontaneous or mechanical ventilation. In this study, we sought to determine the effectiveness of the Laryngeal Tube for primary airway management during routine surgery with mechanical ventilation. One-hundred-seventy-five subjects classifi...

متن کامل

Safe Use of Flammable Endotracheal Tubes During Anesthesia for Laryngeal Laser Surgery-Report of 1024 Cases and a Brief Literature Review

Introduction: One of the major concerns in laryngeal laser surgery is the risk of airway fire. The introduction ofwrapped tubes and metal tubes has reduced the fire hazards. However, these tubes are expensive and do not provide convenient access to the surgical field. There are few laboratory studies addressing the resistance of polyvinylchloride tubes against ignition in the given circum...

متن کامل

مقایسه مقاومت و کمپلیانس دینامیک راه هوایی بین لوله تراشه کافدار و لوله لارنژیال در بیهوشی داخل وریدی کامل(TIVA) Comparing Air Way Resistance and Dynamic Compliance of Tracheal Tube and Laryngeal Tube in TIVA

    Background & Aim: The aim of this study was to compare air way resistance and dynamic compliance of tracheal tube and laryngeal tube in TIVA(Total Intravenous Anesthesia). Nowadays, low airway resistance and dynamic compliance improvement during the mechanical ventilation whether in ICU or during general anesthesia, especially in patients with pulmonary diseases, is a favorable purpose to c...

متن کامل

New Metal Shield for the Endotracheal Tube during Laser Endolaryngeal Surgery

Introduction: To present and assess a newly designed autoclavable, reusable tube shield for an endotracheal tube (ETT) during laser laryngeal surgery.   Materials and Methods: This study included patients scheduled for endolaryngeal laser surgery. A carbonated stainless-steel hemisphere shield (~1.5×0.6 mm) connected to a silk thread passing through a hole in its middle near upper edge was ...

متن کامل

Standard Laryngeal Mask Airway and LMA-ProSeal during laparoscopic surgery.

STUDY OBJECTIVE To compare the frequency of airway seal and sore throat with the LMA-ProSeal (PLMA) and the standard Laryngeal Mask Airway (LMA) during laparoscopic surgery. DESIGN Prospective, controlled, randomized, nonblinded clinical study. SETTING University-affiliated hospital. PATIENTS 60 adult, ASA physical status I, II, and III patients undergoing laparoscopic surgery with genera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Canadian Anaesthetists' Society journal

دوره 27 2  شماره 

صفحات  -

تاریخ انتشار 1980