Influence of valsartan-eluting stent on neointima formation

نویسندگان

  • Li Guihua
  • Lei Wang
  • Jia Sanqing
  • Wenlin Ren
  • Zhao Lin
  • Yao Daokuo
  • Ding Rongjing
چکیده

OBJECTIVE #ENTITYSTARTX02014; This study is to explore the effect of valsartan-eluting stents on neointima formation after stenting and to elucidate possible mechanisms how locally used valsartan prevents in-stent restenosis (ISR). METHOD valsartan- and carriereluting stents were manufactured by using multi-layer-coated technology. Bare stents, carrier-eluting stents and valsartan- eluting stents were implanted into the abdominal aortas of the rabbits respectively. Quantitative angiography (QA) before, immediately after and 3 months after stent implantation were compared between the groups of bare (n=8), carrier-eluting (n=8) and valsartan-eluting stent (n=10), which allows the comparison of vascular diameters of aortas as well as indices of vascular neointimal formation, i.e. luminal area (LA), neointimal area (NIA), inner elastic membrane luminal area (IELA) and the maximal inner-membrane thickness (MIT) in 15 rabbits. α-Actin protein expression were detected by Envision two-step immunohistochemistry. Mean positive indices (MPI) of the above protein were analyzed semi-quantatively by IMS(Information Management System) cell image analysis system. MPI=positive area×OD (optical density). Collagen deposition in neointima was observed through MASSON stain among the three groups. RESULT #ENTITYSTARTX02014; the mean aortic diameters were similar in the three groups:bare stents group(n=8), carrier-eluting stents group(n=8) and valsartan eluting stents group(n=10) measured by QA at different time. A larger luminal area and a less neointimal hyperplasia in valsartan eluting-stents group was found compared with the other two groups. The mean luminal areas were 4345548±125822um(2); 4302061±167952 um(2); 5016269±207934um(2) respectively. The mean neointimal areas were 1119635±163503um(2); 1135636±136555um(2); 441577±74099um(2) and the mean maximal inner-membrane thickness were 210±30um;192±21um; 116±12um respectively. α-Actin protein expression was significantly lower in neointima of valsartan eluting-stents group than the other two groups. Through MASSON stain we found that Collagen was much richer in neointima of bare stents group and carrier-eluting stents group than valsartan eluting-stents group. CONCLUSION #ENTITYSTARTX02014; Valsartan eluting-stents inhibited neointimal hyperplasia after stenting by decreasing collagen deposition and smooth muscle cell proliferation. Therefore it would be potentially effective in preventing in-stent restenosis. ABBREVIATIONS #ENTITYSTARTX02014; Quantitative angiography (QA), luminal area (LA), neointimal area (NIA), inner elastic membrane luminal area (IELA), the maximal inner-membrane thickness (MIT), Mean positive indices (MPI), optical density (OD), Drugeluting stents (DES), in-stent restenosis(ISR), percutaneous transluminal coronary angioplasty (PTCA), angiotensin α type 2 receptor (AT2).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Formation and Transformation of Neointima after Drug-eluting Stent Implantation: Insights from Optical Coherence Tomographic Studies

After coronary stent implantation, neointima formation resembles the wound healing process as it involves the sequential processes of inflammation, granulation, and remodeling. Because antiproliferative drugs and polymers of drug-eluting stents (DESs) delay vascular healing compared with bare metal stents, fibrin deposition can remain long after stent implantation, or inflammation can be excess...

متن کامل

Local delivery of anti-monocyte chemoattractant protein-1 by gene-eluting stents attenuates in-stent stenosis in rabbits and monkeys.

OBJECTIVE We have previously shown that the intramuscular transfer of the anti-monocyte chemoattractant protein-1 (MCP-1) gene (called 7ND) is able to prevent experimental restenosis. The aim of this study was to determine the in vivo efficacy and safety of local delivery of 7ND gene via the gene-eluting stent in reducing in-stent neointima formation in rabbits and in cynomolgus monkeys. METH...

متن کامل

Inhibition of neointima formation by a novel drug-eluting stent system that allows for dose-adjustable, multiple, and on-site stent coating.

OBJECTIVE The risk of in-stent restenosis can be considerably reduced by stents eluting cytostatic compounds. We created a novel drug-eluting stent system that includes several new features in the rapidly evolving field of stent-based drug delivery. METHODS AND RESULTS The aim of the present study was the preclinical evaluation of a stent-coating system permitting individual, on-site coating ...

متن کامل

Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent

Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...

متن کامل

Endothelial cell repopulation after stenting determines in-stent neointima formation: effects of bare-metal vs. drug-eluting stents and genetic endothelial cell modification

AIMS Understanding endothelial cell repopulation post-stenting and how this modulates in-stent restenosis is critical to improving arterial healing post-stenting. We used a novel murine stent model to investigate endothelial cell repopulation post-stenting, comparing the response of drug-eluting stents with a primary genetic modification to improve endothelial cell function. METHODS AND RESUL...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2010