Chemical Assessment of Ballast Water Exchange Compliance: Implementation in North America and New Zealand

نویسندگان

  • Monaca Noble
  • Gregory M. Ruiz
  • Kathleen R. Murphy
چکیده

Fluorescence by naturally occurring dissolved organic matter (FDOM) is a sensitive indicator of ballast water source, with high FDOM in coastal ballast water decreasing typically dramatically when replaced by oceanic seawater during ballast water exchange (BWE). In this study, FDOM was measured in 92 ships arriving at Pacific ports on the US west coast and in New Zealand, and used to assess their compliance with ballast water regulations that required 95% replacement of port water to minimize invasive species risks. Fluorescence in many ships that reported BWEwas significantly higher than is usual for oceanic seawater, and in several cases, significantly higher than in other ships with similar provenance and ballast water management. Pre-exchange source port conditions represented the largest source of uncertainty in the analysis, because residual coastal FDOM when highly fluorescent can significantly influence the fluorescence signature of exchanged ballast water. A meta-analysis comparing the intensities of FDOM in un-exchanged ballast tanks with calculated pre-exchange intensities assuming that ships all correctly implemented and reported BWE revealed notable discrepancies. Thus, the incidence of high-FDOM port waters was seven times lower in reality than would be expected on the basis of these calculations. The results suggest that a significant rate of reporting errors occur due to a combination of factors that may include inadequate BWE and unintentional or deliberate misreporting of ballast water management.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effectiveness of the Ballast Water Exchange Method in Removal of the Heavy Metals in the Ballast Tanks of the Ships, Bushehr Port- Persian Gulf

Ships transport about 80 percent of world trade and transfer approximately three to five billion tons of ballast water internationally every year. Due to the likely presence of pollutants, the ballast water discharged by ships can have negative effects on aquatic ecosystems. This study was conducted on 10 ships that entered the Bushehr port to determine the effectiveness of the ballast water ex...

متن کامل

The Effectiveness of the Ballast Water Exchange Method in Removal of the Heavy Metals in the Ballast Tanks of the Ships, Bushehr Port- Persian Gulf

Ships transport about 80 percent of world trade and transfer approximately three to five billion tons of ballast water internationally every year. Due to the likely presence of pollutants, the ballast water discharged by ships can have negative effects on aquatic ecosystems. This study was conducted on 10 ships that entered the Bushehr port to determine the effectiveness of the ballast water ex...

متن کامل

Paleontology, paleogeography and Paleoenvironment of the Paleocene benthic foraminiferal species of Plummer in the Tethys; a review

Forty two Paleocene benthic foraminiferal species of the Midway Formation in the Gulf Coastal Plain of Texas, USA were firstly investigated by Plummer (1927), and its paleogeographic distribution in some other countries in the Tethyan province were recorded: North America (USA, Mexico), South America (Argentina), Europe (North Sea Basin, Spain, France, Italy, Czech Republic, Bulgaria), North Af...

متن کامل

Ecological predictions and risk assessment for alien fishes in North America.

Methods of risk assessment for alien species, especially for nonagricultural systems, are largely qualitative. Using a generalizable risk assessment approach and statistical models of fish introductions into the Great Lakes, North America, we developed a quantitative approach to target prevention efforts on species most likely to cause damage. Models correctly categorized established, quickly s...

متن کامل

Difficulties in obtaining representative samples for compliance with the Ballast Water Management Convention.

As implementation of the Ballast Water Convention draws nearer a major challenge is the development of protocols which accurately assess compliance with the D-2 Standard. Many factors affect the accuracy of assessment: e.g. large volume of ballast water, the shape, size and number of ballast tanks and the heterogeneous distribution of organisms within tanks. These factors hinder efforts to obta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016