Tablet App halometer for the assessment of dysphotopsia.

نویسندگان

  • Phillip J Buckhurst
  • Shehzad A Naroo
  • Leon N Davies
  • Sunil Shah
  • Hetal Buckhurst
  • Alec Kingsnorth
  • Tom Drew
  • James S Wolffsohn
چکیده

PURPOSE To assess the validity and repeatability of the Aston Halometer. SETTING University clinic, United Kingdom. DESIGN Prospective, repeated-measures experimental study. METHODS The halometer comprises a bright light-emitting-diode (LED) glare source in the center of an iPad4. Letters subtending 0.21° (~0.3 logMAR) were moved centrifugally from the LED in 0.05 degree steps in 8 orientations separated by 45 degrees for each of 4 contrast levels (1000, 500, 100, and 25 Weber contrast units [Cw]) in random order. Bangerter occlusion foils were inserted in front of the right eye to simulate monocular glare conditions in 20 subjects (mean age 27.7 ± 3.1 years). Subjects were positioned 2 meters from the screen in a dark room with the iPad controlled from an iPhone via Bluetooth operated by the researcher. The C-Quant straylight meter was also used with each of the foils to measure the level of straylight over the retina. Halometry and straylight repeatability was assessed at a second visit. RESULTS Halo size increased with the different occlusion foils and target contrasts (F = 29.564, P < .001) as expected and in a pattern similar to straylight measures (F = 80.655, P < 0.001). Lower contrast letters showed better sensitivity but larger glare-obscured areas, resulting in ceiling effects caused by the screen's field-of-view, with 500 Cw being the best compromise. Intraobserver and interobserver repeatability of the Aston Halometer was good (500Cw: 0.84 to 0.93 and 0.53 to 0.73) and similar to the straylight meter. CONCLUSION The halometer provides a sensitive, repeatable way of quantifying a patient-recognized form of disability glare in multiple orientations to add objectivity to subjectively reported discomfort glare.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of dysphotopsia in pseudophakic subjects with multifocal intraocular lenses

Aim To better understand the phenomenon of dysphotopsia in patients implanted with multifocal intraocular lenses (IOLs). Methods Forty-five patients (aged 61.8±8.9 years) implanted bilaterally with Tecnis ZM900 (diffractive multifocal), Lentis Mplus MF30 (segmented refractive multifocal) or Softec-1 (monofocal) IOLs (each n=15) 4-6 months previously and who had achieved a good surgical outcom...

متن کامل

E-Assessment via Apps/modules, Based on the Post Methods Theorizing

The post methods era has witnessed a dramatic change inapproaches to and methods of teaching as well as testing. At the heart of such a change, collaborative learning has received top priority and testing domain has actually gone under scrutiny. This new mode of education has made stakeholders, especially in higher education; reflect on an interactive e-assessment based instruction. Such a cybe...

متن کامل

E-Assessment via Apps/modules, Based on the Post Methods Theorizing

The post methods era has witnessed a dramatic change inapproaches to and methods of teaching as well as testing. At the heart of such a change, collaborative learning has received top priority and testing domain has actually gone under scrutiny. This new mode of education has made stakeholders, especially in higher education; reflect on an interactive e-assessment based instruction. Such a cybe...

متن کامل

Validation of the tablet-administered Brief Assessment of Cognition (BAC App)

Computerized tests benefit from automated scoring procedures and standardized administration instructions. These methods can reduce the potential for rater error. However, especially in patients with severe mental illnesses, the equivalency of traditional and tablet-based tests cannot be assumed. The Brief Assessment of Cognition in Schizophrenia (BACS) is a pen-and-paper cognitive assessment t...

متن کامل

Validation of a Tablet Application for Assessing Dietary Intakes Compared with the Measured Food Intake/Food Waste Method in Military Personnel Consuming Field Rations

The collection of accurate dietary intakes using traditional dietary assessment methods (e.g., food records) from military personnel is challenging due to the demanding physiological and psychological conditions of training or operations. In addition, these methods are burdensome, time consuming, and prone to measurement errors. Adopting smart-phone/tablet technology could overcome some of thes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 41 11  شماره 

صفحات  -

تاریخ انتشار 2015