Treatment for Wear and Osteolysis in Well-Fixed Uncemented TKR
نویسندگان
چکیده
Background. Traditionally, osteolysis around total knee replacements (TKRs) is treated with complete revision. In certain subsets, polyethylene insert exchange and bone grafting may be applicable. This study reports the clinical outcomes for selective bone grafting in patients with osteolysis without complete revision of the TKR. Methods. This retrospective study analyzes 10 TKRs (9 patients, 66.5 ± 6.1 years old) presenting with osteolysis and revised after 8.7 ± 1.9 years of in vivo function. At index TKR, all patients were implanted with uncemented prosthesis and modular polyethylene insert with anteroposterior articular constraint (Ultracongruent, Natural Knee II, Sulzer Medica). The surgical technique for treating the osteolysis included removal of necrotic bone tissue using curettage, filling of the defect with bone graft materials, and polyethylene insert exchange. Results. Patients have not exhibited any further complications associated with osteolysis after 5.1 ± 2.4 years of followup. Routine radiographic exams show total incorporation of the graft material into the previously lytic regions in all patients. Conclusion. In some TKRs with osteolysis and firmly fixed components, the removal of lytic tissue and subsequent defect filling with bone graft materials can be a viable solution. This case series shows complete resolution of osteolysis in all patients with no complications.
منابع مشابه
Reduction of Wear in Fixed Bearing Total Knee Replacement Using Crosslinked Uhmwpe
Introduction Reduction of ultra high molecular weight polyethylene (UHMWPE) surface wear in total knee replacement (TKR) bearings may delay the onset of osteolysis and subsequent loosening of components. Crosslinking has been shown to increase the wear resistance of UHMWPE bearings in multidirectional total hip replacement applications when articulating against smooth counterfaces [1]. The aim ...
متن کاملRisk Factors for Periacetabular Osteolysis and Wear in Asymptomatic Patients with Uncemented Total Hip Arthroplasties
Osteolysis is a silent disease leading to aseptic loosening. This has not been studied in a cohort of asymptomatic patients. The aim of this study was to detect factors that might be associated with the development of periacetabular osteolysis and wear around an uncemented cup. We assessed 206 patients with an uncemented cup, measuring wear and periacetabular osteolysis using computed tomograph...
متن کاملHumeral-sided Radiographic Changes Following Reverse Total Shoulder Arthroplasty
Background: We sought to characterize humeral-sided radiographic changes at a minimum of 2 years after reverseshoulder arthroplasty (RSA) to determine their association with specific implantation techniques.Methods: The immediate and most recent postoperative anteroposterior radiographs of 120 shoulders with primary RSAand a minimum of 2-years of radiographic follow-up were an...
متن کاملWear particles and ions from cemented and uncemented titanium-based hip prostheses—A histological and chemical analysis of retrieval material
Wear debris-induced inflammation is considered to be the main cause for periprosthetic osteolysis in total hip replacements (THR). The objective of this retrieval study was to examine the tissue reactions and exposure to metal ions and wear particles in periprosthetic tissues and blood samples from patients with titanium (Ti)-based hip prostheses that were revised due to wear, osteolysis, and/o...
متن کاملResults of uncemented porous-coated anatomic total hip replacement.
We reviewed a consecutive series of 241 uncemented, porous-coated anatomic (PCA) hip replacements at an average follow-up of five years (2 to 9). Of these, 32 had failed (13%), 26 at the acetabular component (11%) and six at the femoral component (2%). Acetabular failure was associated with local osteolysis and excessive polyethylene wear in 20 cases: in these histological examination showed gi...