Pii: S1010-7940(02)00039-8
نویسندگان
چکیده
Objectives: There has been no method which can measure regional myocardial blood flow in real-time and continuously. The purpose of this study was to validate myocardial blood flow measurement using a thermal diffusion method. For this purpose, myocardial blood flow measurement was performed using the thermal diffusion method and the electrolytic hydrogen clearance method. Methods: Seven pigs were used for this study, six were for comparison between the thermal diffusion and electrolytic hydrogen clearance methods, and one was for demonstration of myocardial blood flow measurement using the thermal diffusion method on a beating heart coronary artery bypass model with ischemic preconditioning. Results: A good correlation was found between myocardial blood flow values obtained by the electrolytic hydrogen clearance method and 1/V values obtained by a thermal diffusion probe, the correlation coefficient was 0.841 (P , 0:001). During the beating heart coronary artery bypass, the regional myocardial blood flow was recorded in real-time and continuously. Conclusions: This study demonstrated measurement of regional myocardial blood flow using the thermal diffusion method for the first time and simultaneous measurement using the electrolytic hydrogen clearance method for calibration. It provided a real-time and continuous myocardial blood flow measurement and has a potential to contribute to progress in beating-heart surgery. q 2002 Elsevier Science B.V. All rights reserved.
منابع مشابه
Pii: S1010-7940(02)00724-8
Aortobronchial fistula is a rare complication following thoracic aortic operations and is invariably fatal if not promptly diagnosed and repaired. Direct prosthetic repair carries a risk of graft repair sepsis and fistula recurrence. We describe two cases presenting with aortobronchial fistula following coarctation repair which were successfully treated by different surgical approaches. q 2002 ...
متن کاملPii: S1010-7940(02)00020-9
Electrocautery has a potential risk of serious pacemaker dysfunction in patients with implanted pacemaker. Here we present the safe and efficient use of ultrasonic scalpel (Harmonic scalpel) for the first time in a patient with implanted pacemaker undergoing open-heart reoperation. q 2002 Elsevier Science B.V. All rights reserved.
متن کاملPii: S1010-7940(02)00664-4
This report describes the formation of a true aneurysm 15 years after an internal mammary artery patch aortoplasty of an aortic coarctation. A true aneurysm was confirmed on histology. To our knowledge, this is the first report of a case with such a complication. q 2002 Published by Elsevier Science B.V.
متن کاملPii: S1010-7940(02)00369-x
Lipomatous hypertrophy of the interatrial septum is an uncommon entity that usually occurs in elderly patients. We report a patient who presented with atrial fibrillation, congestive cardiac failure and a large intracavitary mass in the right atrium on echocardiography. He underwent successful resection of the mass with septal reconstruction. Pathology was consistent with lipomatous hypertrophy...
متن کاملPii: S1010-7940(02)00349-4
Arterial pseudoaneurysm has been reported as a possible complication of immunodeficiency virus infection. We report two cases of HIVpositive patients with a pseudoaneurysm at the level of the descending thoracic aorta. The first patient refused surgery and has been followed up to 14 months, whereas the second patient underwent successful surgical repair. The importance of magnetic resonance ima...
متن کاملPii: S1010-7940(02)00396-2
We present rupture of lung hydatid cyst in a patient with multiple organ involvement during albendazole treatment. The patient was first provided mechanical ventilation than residue cavity and the other intact cyst was treated surgically. We concluded that albendazole should be used in postoperative period in patients with hydatid disease of the lung to prevent recurrent disease. q 2002 Elsevie...