Lung lobectomy in a patient with an implantable left ventricular assist device.
نویسندگان
چکیده
Non-cardiac surgical procedures in patients with left ventricular assist devices (LVADs) pose a special challenge given the hemodynamic and hematologic considerations in these patients. During pulmonary procedures in patients with LVADs, special attention should be paid to hemodynamics because lung resection surgery requires a lateral decubitus position, single-lung ventilation and postoperative decrease in the pulmonary vascular bed, all of which may lead to inadequate preload to the LVAD. We present a case of lower lobectomy of the left lung for an adenocarcinoma found in a patient with an implantable continuous-flow LVAD.
منابع مشابه
Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملApplication of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملAdverse interaction between a left ventricular assist device and an implantable cardioverter defibrillator.
An increasing number of patients have a coexisting implantable cardioverter defibrillator (ICD) and left ventricular assist device (LVAD) to treat ventricular arrhythmias and refractory heart failure, respectively. To date, there have been no published reports of negative interactions between these devices that have impacted appropriate ICD or LVAD function. In this case report, we describe a p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 13 6 شماره
صفحات -
تاریخ انتشار 2011