Which pivot calibration?

نویسنده

  • Ziv Yaniv
چکیده

Estimating the location of a tracked tool’s tip relative to its Dynamic Reference Frame (DRF) and localizing a specific point in a tracking system’s coordinate frame are fundamental tasks in image-guided procedures. The most common approach to estimating these values is by pivoting a tool around a fixed point. The transformations from the tracking system’s frame to the tool’s DRF are the input. The output is the translation from the DRF to the tool’s tip and the translation from the tracker’s frame to the pivoting point. While the input and output are unique, there are multiple mathematical formulations for performing this estimation task. The question is, are these formulations equivalent in terms of precision and accuracy? In this work we empirically evaluate three common formulations, a geometry based sphere fitting formulation and two algebraic formulations. In addition we evaluate robust variants of these formulations using the RANSAC framework. Our evaluation shows that the algebraic formulations yield estimates that are more precise and accurate than the sphere fitting formulation. Using the Vicra optical tracking system from Northern Digital Inc., we observed that the algebraic approaches have a mean(std) precision of 0.25(0.11)mm localizing the pivoting point relative to the tracked DRF, and yield a fiducial registration error with a mean(std) 0.15(0.08)mm when registering a precisely constructed divot phantom to the localized points in the tracking system’s frame. The sphere fitting formulation yielded less precise and accurate results with a mean(std) of 0.35(0.21)mm for precision and 0.25(0.14)mm for accuracy. The robust versions of these formulations yield similar results even when the data is contaminated with 30% outliers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of surgical tool-tip tracking error distribution in coordinate reference frame involving pivot calibration uncertainty

Accurate understanding of surgical tool-tip tracking error is important for decision making in image-guided surgery. In this Letter, the authors present a novel method to estimate/model surgical tool-tip tracking error in which they take pivot calibration uncertainty into consideration. First, a new type of error that is referred to as total target registration error (TTRE) is formally defined ...

متن کامل

Propagation of soft tissue artifacts to the center of rotation: a model for the correction of functional calibration techniques.

This paper presents a mathematical model for the propagation of errors in body segment kinematics to the location of the center of rotation. Three functional calibration techniques, usually employed for the gleno-humeral joint, are studied: the methods based on the pivot of the instantaneous helical axis (PIHA) or the finite helical axis (PFHA), and the "symmetrical center of rotation estimatio...

متن کامل

Pbm and Activated Sludge Flocculation: from Experimental Data to a Calibrated Model

A calibration methodology is presented for a Population Balance Model (PBM) using on-line flocculation data. The moving pivot discretisation technique is preferred to solve the PBM. A methodology for grid transformation and volume to number transformation is presented. Model fits on volume-based fitting variables fit the middle part of both the vol% and number distribution better, but under pre...

متن کامل

Measuring the inertial properties of a tennis racket

Simple and bifilar pendulum were used to measure the mass moments of inertia of three tennis rackets. The pendulum setups were filmed using an off-the-shelf camcorder, with a stopwatch in view to provide timing data. The measurement accuracy was assessed using calibration rods of known mass moment of inertia. The simple pendulum method was found to be most accurate (<1.0 % difference to theoret...

متن کامل

Thrust stand for vertically oriented electric propulsion performance evaluation.

A variation of a hanging pendulum thrust stand capable of measuring the performance of an electric thruster operating in the vertical orientation is presented. The vertical orientation of the thruster dictates that the thruster must be horizontally offset from the pendulum pivot arm, necessitating the use of a counterweight system to provide a neutrally stable system. Motion of the pendulum arm...

متن کامل

Investigation of infiltration in Center Pivot irrigation system

Use of the double ring infiltrometer to measure soil water infiltration in center pivot irrigation systems isn&rsquo;t an accurate approach because the real conditions of infiltration under center pivot sprinklers is different from what happens in the double ring. In this study the infiltration parameters were evaluated in real conditions of a center pivot system. For this purpose a single ring...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015