Characterization of a CH planar laser-induced fluorescence imaging system using a kHz-rate multimode-pumped optical parametric oscillator.

نویسندگان

  • Joseph D Miller
  • Sascha R Engel
  • Johannes W Tröger
  • Terrence R Meyer
  • Thomas Seeger
  • Alfred Leipertz
چکیده

The performance characteristics of a new CH planar laser-induced fluorescence (PLIF) imaging system composed of a kHz-rate multimode-pumped optical parametric oscillator (OPO) and high-speed intensified CMOS camera are investigated in laminar and turbulent CH4-H2-air flames. A multi-channel Nd:YAG cluster that produces up to 225 mJ at 355 nm with multiple-pulse spacing of 100 μs (corresponding to 10 kHz) is used to pump an OPO to produce up to 6 mJ at 431 nm for direct excitation of the A-X (0, 0) band of the CH radical. Single-shot signal-to-noise ratios of 82:1 and 7.5:1 are recorded in laminar premixed flames relative to noise in the background and within the flame layer, respectively. The spatial resolution and image quality are sufficient to accurately measure the CH layer thickness of ~0.4 mm while imaging the detailed evolution of turbulent flame structures over a 20 mm span. Background interferences due to polycyclic-aromatic hydrocarbons and Rayleigh scattering are minimized and, along with signal linearity, allow semi-quantitative analysis of CH signals on a shot-to-shot basis. The effects of design features, such as cavity finesse and passive injection seeding, on conversion efficiency, stability, and linewidth of the OPO output are also discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-speed CH planar laser-induced fluorescence imaging using a multimode-pumped optical parametric oscillator.

We report on high-speed CH planar laser-induced fluorescence (PLIF) imaging in turbulent diffusion flames using a multimode-pumped optical parametric oscillator (OPO). The OPO is pumped by the third-harmonic output of a multimode Nd:YAG cluster for direct signal excitation in the A-X (0,0) band of the CH radical. The lasing threshold, conversion efficiency, and linewidth are shown to depend on ...

متن کامل

Ultrahigh-frame-rate OH fluorescence imaging in turbulent flames using a burst-mode optical parametric oscillator.

Burst-mode planar laser-induced fluorescence (PLIF) imaging of the OH radical is demonstrated in laminar and turbulent hydrogen-air diffusion flames with pulse repetition rates up to 50 kHz. Nearly 1 mJ/pulse at 313.526 nm is used to probe the OH P(2)(10) rotational transition in the (0,0) band of the A-X system. The UV radiation is generated by a high-speed-tunable, injection-seeded optical pa...

متن کامل

High-repetition-rate femtosecond optical parametric oscillator-amplifier system near 3 mm

An ultrafast laser system for the chemically important 3-mm spectral region has been constructed by means of noncritically phased-matched KTiOPO4 optical parametric gain elements. An optical parametric oscillator, synchronously pumped by a mode-locked Ti:sapphire oscillator, generates high-quality seed pulses for an optical parametric amplifier. The optical parametric amplifier, pumped by a hig...

متن کامل

High-Speed Multi-Line OH Planar Laser-Induced Fluorescence in Unsteady Flames

We describe the further development and application of a dual-injection-seeded optical parametric oscillator and associated kHz-rate burst-mode pump laser for high-speed OH planar laser-induced fluorescence in unsteady flames. A detailed overview of the novel double-pulse configuration of the burst-mode laser is given, indicating the potential for use in systems where both high energy and high ...

متن کامل

Quasi-continuous burst-mode laser for high-speed planar imaging.

The pulse-burst duration of a compact burst-mode Nd:YAG laser is extended by one order of magnitude compared to previous flashlamp-pumped designs by incorporating a fiber oscillator and diode-pumped solid-state amplifiers. The laser has a linewidth of <2 GHz at 1064.3 nm with 150 mJ per individual pulse at 10 kHz. The performance of the system is evaluated by using the third-harmonic output at ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 51 14  شماره 

صفحات  -

تاریخ انتشار 2012