Immobilized-enzyme nylon-tube reactors for routine determination of urea and citrulline in serum.

نویسندگان

  • P V Sundaram
  • M P Igloi
  • R Wassermann
  • W Hinsch
  • K J Knoke
چکیده

A continuous-flow clinical analyzer for the routine estimation of urea is described that makes use of an immobilized-enzyme nylon-tube reactor as part of a flow-through system (a Technicon AutoAnalyzer I). Results of blood-urea analyses by use of the immobilized urease are compared with determinations made with the diacetyl monoxime method and the urease solution method. Clinical trials carried out routinely with the immobilized enzyme nylon tube reactor give reliable and reproducible results with high precision and low cost. The reactors are stable to intermittent or continued use for at least four months or for 2000 tests. A method is described in which differential colorimetry is used for determining citrulline in blood and which makes use of the immobilized urease, albeit indirectly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single- and coupled-enzyme nylon tube reactors for routine determination of pyruvate and lactate in serum.

We describe the use of a continuous-flow clinical analyzer with an immobilized coupled-enzyme nylon tube reactor and an immobilized single-enzyme nylon tube reactor for routine estimation of lactate and pyruvate in serum. These reactors are incorporated into the flow system of a modified continuous-flow analyzer (Technicon AutoAnalyzer). Results for serum lactate and pyruvate by this method are...

متن کامل

Single- and coupled-enzyme nylon-tube reactors for plasma glucose determination with glucose oxidase and aldehyde dehydrogenase.

We describe routine methods for determining glucose in plasma with use of aldehyde dehydrogenase or glucose oxidase-aldehyde dehydrogenase immobilized in a nylon tube that is integrated into a continuous-flow system. Although the coupled-enzyme nylon-tube reactors require the presence of a third enzyme, catalase, in solution, the kinetics are not so complicated as to preclude reliable routine d...

متن کامل

Immobilized-enzyme nylon-tube reactor for routine determination of uric acid in serum.

We report here the preparation of an immobilized-enzyme nylon-tube reactor containing uricase (EC 1.7.3.3) and the assembly of a flow-through system (Technicon AutoAnalyzer II) for the routine determination of uric acid in serum. Results of these uric acid analyses by use of immobilized uricase, in conjunction with peroxidase (EC 1.11.1.7) and aminophenazone-dichlorophenol in solution, are comp...

متن کامل

The use of immobilized enzyme reactors in continuous-flow analyzers for the determination of glucose, urea, and uric acid.

We describe the use of immobilized enzymes in assay methods for the determination of glucose with glucose oxidase, uric acid with uricase, and urea with urease in serum samples. The enzyme reactor tubes were adapted to continuous-flow analyzers (Technicon AA II, SMA 12/60, and SMAC) used in routine laboratory determinations, and results with their use were compared to those from assays involvin...

متن کامل

Routine glucose determination in serum by use of an immobilized glucose dehydrogenase nylon-tube reactor.

We report a method for immobilizing glucose dehydrogenase on the inside surface of nylon tubes to produce an immobilized-enzyme nylon-tube reactor. The glucose dehydrogenase reactor is integrated into the flow system of a continuous-flow analyzer to facilitate routine analysis of serum glucose at 50 samples/h. We compared results with those by the reference hexokinase/glucose-6-phosphate dehydr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 2  شماره 

صفحات  -

تاریخ انتشار 1978