Spectrum of echocardiographic findings in tricuspid valve endocarditis.
نویسندگان
چکیده
This report describes a spectrum of M-mode and cross-sectional echocardiographic abnormalities in eight patients with infective endocarditis of the tricuspid valve. The M-mode echocardiogram of the tricuspid valve was abnormal in all but one patient in whom abnormal echoes were seen anterior to the tricuspid valve, in the right ventricular cavity and right ventricular outflow tract. Six patients had shaggy echoes on the tricuspid valve; and one patient showed multilayered echoes on the tricuspid valve which resembled a right atrial myxoma. Irregular diastolic fluttering of the tricuspid valve, indicative of ruptured chordae tendineae, was noted in three patients. The cross-sectional echocardiogram showed abnormal thick shaggy echoes on the tricuspid valve in all five patients on whom the procedure was performed. Contrast echocardiography confirmed the presence of tricuspid regurgitation in four patients. We conclude that echocardiography is useful in the diagnosis of tricuspid valve vegetations, and in detecting complications such as ruptured chordae tendineae and tricuspid regurgitation.
منابع مشابه
Tricuspid Valve Endocarditis in an Intravenous Drug Abuser: A Case Report
Recently, there have been more reports of cardiac valve infections due to the increasing number of intravenous (IV) drug abusers and chronic renal failure patients. Among cardiac valves, tricuspid valve is most commonly affected in the course of endocarditis. Appropriate management of these patients is a challenging and controversial issue in the field of cardiac surgery. Treatment options in s...
متن کاملEchocardiographic findings after tricuspid valvectomy.
Resection of the tricuspid valve without prosthetic replacement has successfully been performed in patients with tricuspid valvular endocarditis. Using M-mode, two-dimensional, and Doppler echocardiograms, we studied four patients who underwent tricuspid valvectomy. All patients had previous history of intravenous drug abuse and staphylococcal endocarditis with tricuspid valvular involvement. I...
متن کاملEchocardiographic detection of tricuspid valve prolapse.
The echocardiographic findings in 12 patients with tricuspid valve prolapse are presented. Eight of these patients had associated mitral valve prolapse. Only one of the above patients had the characteristic physical signs of tricuspid incompetence. Two types of abnormality were noted on the echocardiogram of the tricuspid valve. In eight patients, the systolic segment of the tricuspid valve sho...
متن کاملPhysiological Valvular Regurgitation
availability of a new tool it is incumbent on clinical investigators to develop guidelines for defining the normal range of findings. Many recent studies have suggested that with improving sensitivity of Doppler ultrasound devices, valvular regurgitation may be detected through the tricuspid valves of as many as 95% of the healthy subjects in some series,3 92% of pulmonary valves,4 and a variab...
متن کاملPhysiological Valvular Regurgitation
availability of a new tool it is incumbent on clinical investigators to develop guidelines for defining the normal range of findings. Many recent studies have suggested that with improving sensitivity of Doppler ultrasound devices, valvular regurgitation may be detected through the tricuspid valves of as many as 95% of the healthy subjects in some series,3 92% of pulmonary valves,4 and a variab...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 42 5 شماره
صفحات -
تاریخ انتشار 1979