Recording depth and signal competition in heterodyne interferometry.

نویسندگان

  • Ombeline de La Rochefoucauld
  • Shyam M Khanna
  • Elizabeth S Olson
چکیده

A common way to measure submicroscopic motion of the organ of Corti is heterodyne interferometry. The depth over which vibration can be accurately measured with heterodyne interferometry is determined by both the optics, which controls to what extent light from nonfocal planes reaches the photodetectors, and demodulation electronics, which determines to what extent signal generated by out-of-focal-plane light influences the measurements. The influence of a second reflecting surface is investigated theoretically and experimentally. By reviewing the theory of FM demodulation and showing tests with a Revox FM demodulator, it is demonstrated that the influence of a secondary signal on a measurement depends on the modulation index. Both high- and low-modulation index signals are encountered in heterodyne interferometry of the cochlea. Using a He-Ne-like diode laser (lambda = 638 nm), the border between low- and high-modulation signals is at a displacement of about 25-100 nm. Confocal interferometry reduces the magnitude of out-of-focus signals, and therefore their effect on vibration measurement. The response of the confocal system to reflected signals from two surfaces separated by distances encountered within the cochlear partition is shown. The results underscore the benefit of steep optical sectioning for intracochlear measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Signal competition in optical coherence tomography and its relevance for cochlear vibrometry.

The usual technique for measuring vibration within the cochlear partition is heterodyne interferometry. Recently, spectral domain phase microscopy (SDPM) was introduced and offers improvements over standard heterodyne interferometry. In particular, it has a penetration depth of several mm due to working in the infrared range, has narrow and steep optical sectioning due to using a wideband light...

متن کامل

Random depth access full-field heterodyne low-coherence interferometry utilizing acousto-optic modulation and a complementary metaloxide semiconductor camera.

With analog scanning, time-domain low-coherence interferometry lacks precise depth information, and optical carrier generation demands a linear scanning speed. Full-field heterodyne low-coherence interferometry that uses a logarithmic complementary metal-oxide semiconductor camera, acousto-optic modulation, and digital depth stepping is reported, with which random regions of interest, lateral a...

متن کامل

HOLOGRAPHIC INTERFEROMETRY WITH AN INJECTION SEEDED Nd:YAG LASER AND TWO REFERENCE BEAMS

The performance of twin injection seeded Nd:YAG lasers is compared with the performance of an argon-ion laser for recording dual-reference-beam holograms in AGFA 8356 emulsion. Optical heterodyning is used to measure interference, and the results are expressed in terms of heterodyning signal level and inteiisity signal-to-noise. The Nd:YAG laser system is to be used for optical inspections of s...

متن کامل

HOLOGRAPHIC INTERFEROMETRY WITH AN INJECTION SEEDED Nd:YAG LASER AND TWO REFERENCE BEAMS

The performance of twin injection seeded Nd:YAG lasers is compared with the performance of an argon-ion laser for recording dual-reference-beam holograms in AGFA 8356 emulsion. Optical heterodyning is used to measure interference, and the results are expressed in terms of heterodyning signal level and inteiisity signal-to-noise. The Nd:YAG laser system is to be used for optical inspections of s...

متن کامل

Experimental comparison of autodyne and heterodyne laser interferometry using a Nd:YVO4 microchip laser

Using a Nd:YVO 4 microchip laser with a relaxation frequency in the megahertz range, we have experimentally compared a heterodyne interferometer based on a Michelson configuration with an autodyne interferometer based on the laser optical feedback imaging (LOFI) method regarding their signal to noise ratios. In the heterodyne configuration, the beating between the reference beam and the signal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 117 3 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2005