Systematic errors in Hadamard transform optics.

نویسندگان

  • N J Sloane
  • M Harwit
  • M H Tai
چکیده

This paper analyzes the systematic errors in Hadamard transform optical instruments caused by moving masks, incorrect mask alignment, faulty mask fabrication, missing data, diffraction, etc. and describes techniques for reducing or eliminating these errors. In a great many cases the behavior of the instrument can be characterized by a single matrix equation of the form eta = TWa + e, where the components of eta are the measurements, T is a matrix characterizing the instrument, W specifies the mask configurations, a is a vector containing the unknown spectral intensities, and the components of e are small random errors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Masks for Hadamard transform optics, and weighing designs.

This paper gives a brief survey of the design of masks for Hadamard spectrometers and image scanners. Three different criteria are described for judging a mask, as well as techniques for choosing masks that are not too far from the optimum.

متن کامل

Hadamard-transform spectrometry of the atmospheres of Earth and jupiter.

A Hadamard-transform spectrometer has been used to obtain a spectrum of Jupiter from 880 cm(-1) to 770cm(-1) Three ammonia absorption features stand out at 870 cm(-1), 851 cm(-1), and 833 cm(-1). The general shape of the spectrum implies an atmosphere with a monotonically decreasing temperature profile up to the 125 K level. In addition, transmission profiles of the earth's atmosphere were take...

متن کامل

Identification of Yarn Periodical Errors Using Signal Processing Techniques Based on Capacitive and Optical Sensors Measurements

This paper presents a study to identify the type and location of yarn periodical errors applying three different signal processing approaches based on FFT – Fast Fourier Transform, FWHT-Fast Walsh-Hadamard Transform and FDFI – Fast Impulse Frequency Determination. The errors determination is applied for the mass measurement of yarn using a capacitive sensor and for the measurement of yarn diame...

متن کامل

Regular symmetric Hadamard matrices with constant diagonal

We survey constructions of regular symmetric Hadamard matrices with constant diagonal, and point out some errors in the literature.

متن کامل

Characterization of a compressive imaging system using laboratory and natural light scenes.

Compressive imagers acquire images, or other optical scene information, by a series of spatially filtered intensity measurements, where the total number of measurements required depends on the desired image quality. Compressive imaging (CI) offers a versatile approach to optical sensing which can improve size, weight, and performance (SWaP) for multispectral imaging or feature-based optical sen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 17 18  شماره 

صفحات  -

تاریخ انتشار 1978