Estimation of the Human Extrathoracic Deposition Fraction of Inhaled Particles Using a Polyurethane Foam Collection Substrate in an IOM Sampler

نویسندگان

  • Darrah K. Sleeth
  • Susan A. Balthaser
  • Scott Collingwood
  • Rodney R. Larson
چکیده

Extrathoracic deposition of inhaled particles (i.e., in the head and throat) is an important exposure route for many hazardous materials. Current best practices for exposure assessment of aerosols in the workplace involve particle size selective sampling methods based on particle penetration into the human respiratory tract (i.e., inhalable or respirable sampling). However, the International Organization for Standardization (ISO) has recently adopted particle deposition sampling conventions (ISO 13138), including conventions for extrathoracic (ET) deposition into the anterior nasal passage (ET₁) and the posterior nasal and oral passages (ET₂). For this study, polyurethane foam was used as a collection substrate inside an inhalable aerosol sampler to provide an estimate of extrathoracic particle deposition. Aerosols of fused aluminum oxide (five sizes, 4.9 µm-44.3 µm) were used as a test dust in a low speed (0.2 m/s) wind tunnel. Samplers were placed on a rotating mannequin inside the wind tunnel to simulate orientation-averaged personal sampling. Collection efficiency data for the foam insert matched well to the extrathoracic deposition convention for the particle sizes tested. The concept of using a foam insert to match a particle deposition sampling convention was explored in this study and shows promise for future use as a sampling device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Porous Polyurethane Foam for Use as a Particle Collection Substrate in a Nanoparticle Respiratory Deposition Sampler.

Porous polyurethane foam was evaluated to replace the eight nylon meshes used as a substrate to collect nanoparticles in the Nanoparticle Respiratory Deposition (NRD) sampler. Cylindrical (25-mm diameter by 40-mm deep) foam with 110 pores per inch was housed in a 25-mm-diameter conductive polypropylene cassette cowl compatible with the NRD sampler. Pristine foam and nylon meshes were evaluated ...

متن کامل

Micro Particles Transport and Deposition in Realistic Geometry of Human Upper Airways

Realistic geometry of human upper airways from mouth to the end of trachea was reconstructed by implementing the CT-Scan images of a male subject.   A computational model for analyzing the airflow in the airways was developed and several simulations were performed.  To capture the anisotropy of the inhaled airflow in the upper airways, the Reynolds stress transport model of turbulence was used ...

متن کامل

Application of porous foams for size-selective measurements of airborne wheat allergen.

BACKGROUND Exposure to airborne wheat allergen is a well-known cause of bakers' allergy and asthma. Airborne wheat allergen can be measured by enzyme immunoassays (EIAs) in extracts of inhalable dust samples, but only limited knowledge is available on the size distribution of wheat allergen-carrying particles. Recently, a new sampling medium, porous polyurethane foam, has been introduced for th...

متن کامل

Development of a sampler to estimate regional deposition of aerosol in the human respiratory tract.

A multistage sampler was developed and tested to estimate regional deposition of aerosol in the human respiratory system. The motivation for this research is to improve our ability to estimate inhaled aerosol dose. Current methods for aerosol measurement and exposure/risk assessment are based on particle aspiration (e.g. inhalable PM) or on penetration to various regions of the respiratory syst...

متن کامل

Determination of hexamethylene-based isocyanates in spray-painting operations. Part 1. Evaluation of a polyurethane foam sponge sampler.

A polyurethane foam (PUF) sponge was mounted in a cassette sampler and evaluated as a sorbent for the collection of hexamethylene diisocyanate (HDI) monomer and HDI-based oligomers. Recovery studies indicated 112 +/- 34% average recovery of HDI monomer and 92 +/- 9% and 97 +/- 25% average recovery of HDI-based oligomers when using impregnated PUF sponges. The PUF sponge was also evaluated durin...