A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note.

نویسنده

  • I Paddick
چکیده

A conformity index is a measure of how well the volume of a radiosurgical dose distribution conforms to the size and shape of a target volume. Because the success of radiosurgery is related to the extremely conformal irradiation of the target, an accurate method for describing this parameter is important. Existing conformity ratios and indices used in radiosurgery are reviewed and criticized. It will be demonstrated that previously proposed measurements of conformity can, under certain conditions, give false perfect scores. A new conformity index is derived that gives an objective score of conformity for a treatment plan and gives no false scores. An analysis of five different treatment plans is made using both the existing scoring methods and the new conformity index.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CyberKnife® radiosurgery in the treatment of complex skull base tumors: analysis of treatment planning parameters

BACKGROUND Tumors of the skull base pose unique challenges to radiosurgical treatment because of their irregular shapes, proximity to critical structures and variable tumor volumes. In this study, we investigate whether acceptable treatment plans with excellent conformity and homogeneity can be generated for complex skull base tumors using the Cyberknife radiosurgical system. METHODS At Georg...

متن کامل

Dosimetric comparison of CyberKnife with other radiosurgical modalities for an ellipsoidal target.

OBJECTIVE To compare treatment plans obtained with the CyberKnife (CK) (Accuray, Inc., Sunnyvale, CA) with those of other commonly used radiosurgical modalities, such as the gamma knife (GK), linear accelerator multiple arcs, conformally shaped static fields, and intensity-modulated radiotherapy (IMRT). METHODS An ellipsoidal simulated target was chosen centrally located in a three-dimensiona...

متن کامل

Comparison and evaluation of dosimetric and radiobiological parameters in two different treatment plans in stomach cancer by use of 3D CRT

Introduction: In 3DCRT the number of therapeutic fields has dramatic impact on treatment results especially in stomach cancer. Traditionally, for radiotherapy of stomach cancer the therapeutic procedure was using two fields (AP- PA or AP Lateral with wedge) to achieve smooth and homogeneous dose distribution in tumor. But nowadays, adding lateral or oblique fields to aforement...

متن کامل

Dosimetric evaluation of field-in-field and sliding-window IMRT in endometrium cancer patients with a new approach for the conformity index

Background: Purpose of the study is to evaluate field-in-field (FIF) and sliding-window intensity modulated radiation therapy (SW-IMRT) treatment plans in terms of homogeneity index (HI), conformity index (CI) and normal tissue doses for organs at risk (OAR) in patients with endometrial carcinoma along with deriving a new expression for CI. Materials and Methods: Four different FIF plans with d...

متن کامل

Comparison between field-in-field technique and the use of conventional wedges for treatment planning of esophageal cancer

Introduction: This study was conducted to evaluate and quantify the treatment planning performance of MLC-optimized field-in-field planning technique (FIF), also named forward IMRT, versus wedge-based three field (W3F) technique in terms of dosimetric and radiobiological parameters for esophageal carcinoma.   Material and Methods: Twenty patients with esophag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurosurgery

دوره 93 Suppl 3  شماره 

صفحات  -

تاریخ انتشار 2000