Studies on left atrial automaticity in dogs.

نویسندگان

  • M Mirowski
  • S H Lau
  • G A Bobb
  • C Steiner
  • A N Damato
چکیده

The site of origin and the sequence of atrial activation were studied in 21 open-chested dogs anesthetized with sodium pentobarbital. Bipolar plunge electrodes were used to record atrial electrograms simultaneously with surface lead II and His bundle electrogram. In sinus rhythm the sinus node was activated first, followed sequentially by Bachmann's bundle, right atrial appendix, left atrial appendix, posterior left atrium, and the proximal portion of the coronary sinus. In 15 dogs left atrial beats and rhythms of various rate were recorded, including instances of left atrial exit block and of rapid left atrial rhythms. In such beats one of the left atrial electrodes was activated first and was followed by Bachmann's bundle, sinus node, proximal portion of the coronary sinus, and by right atrial appendix. Left atrial beats were observed occurring (1) spontaneously; (2) as a result of vagal stimulation; (3) after destruction of the sinus node; (4) during ventricular pacing. Left atrial pacing through the electrode recording initial activity reproduced the sequence and configuration of atrial electrogram similar to that seen in the ectopic left atrial beats. These results demonstrate that in dogs ectopic activity frequently originates in the left atrium. ADDITIONAL

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chronic Valve Disease and Left Atrial Splitting in the Dog [Dissertation]

Age, sex, and breed evaluations of 392 dogs with chronic valve disease (CVD) from a survey of 4,831 dogs revealed a predominance of CVD in purebred male dogs. Male Cocker Spaniels were most frequently affected. A questionnaire survey concerning aspects of medical history, environment, behavior, and survival was made 3-5 years after initial clinical examinations on 471 dogs. This study revealed ...

متن کامل

A Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures

Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...

متن کامل

Reference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs

Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...

متن کامل

GIucagon-Enhanced Ventricular Automaticity in Dogs

Ventricular automaticity was studied in dogs with intact atrioventricular conduction systems and in dogs with surgically interrupted conduction systems before and after glucagon, 50 fig/kg. Results of these studies are in agreement with previous studies. When the influence of rate-dependent suppression of ventricular automaticity was nullified by comparing automaticity during periods of equal h...

متن کامل

Effects of glucagon on atrioventricular conduction and ventricular automaticity in dogs.

The effects of glucagon, 50 |iig/kg, on atrioventricular (A-V) conduction and ventricular automaticity were studied in 14 dogs. Atrial pacing was used to control the heart rate. The His bundle electrogram was recorded, and the interval from the pacing impulse (P) to the His bundle spike (H), the P-H interval, was used as a measure of A-V conduction. Ventricular automaticity was estimated in fou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 26 3  شماره 

صفحات  -

تاریخ انتشار 1970