Effects of Neurally Adjusted Ventilatory Assist (NAVA) levels in non-invasive ventilated patients: titrating NAVA levels with electric diaphragmatic activity and tidal volume matching
نویسندگان
چکیده
BACKGROUND Neurally adjusted ventilatory assist (NAVA) delivers pressure in proportion to diaphragm electrical activity (Eadi). However, each patient responds differently to NAVA levels. This study aims to examine the matching between tidal volume (Vt) and patients' inspiratory demand (Eadi), and to investigate patient-specific response to various NAVA levels in non-invasively ventilated patients. METHODS 12 patients were ventilated non-invasively with NAVA using three different NAVA levels. NAVA100 was set according to the manufacturer's recommendation to have similar peak airway pressure as during pressure support. NAVA level was then adjusted ±50% (NAVA50, NAVA150). Airway pressure, flow and Eadi were recorded for 15 minutes at each NAVA level. The matching of Vt and integral of Eadi (ʃEadi) were assessed at the different NAVA levels. A metric, Range90, was defined as the 5-95% range of Vt/ʃEadi ratio to assess matching for each NAVA level. Smaller Range90 values indicated better matching of supply to demand. RESULTS Patients ventilated at NAVA50 had the lowest Range90 with median 25.6 uVs/ml [Interquartile range (IQR): 15.4-70.4], suggesting that, globally, NAVA50 provided better matching between ʃEadi and Vt than NAVA100 and NAVA150. However, on a per-patient basis, 4 patients had the lowest Range90 values in NAVA100, 1 patient at NAVA150 and 7 patients at NAVA50. Robust coefficient of variation for ʃEadi and Vt were not different between NAVA levels. CONCLUSIONS The patient-specific matching between ʃEadi and Vt was variable, indicating that to obtain the best possible matching, NAVA level setting should be patient specific. The Range90 concept presented to evaluate Vt/ʃEadi is a physiologic metric that could help in individual titration of NAVA level.
منابع مشابه
Impact of prolonged assisted ventilation on diaphragmatic efficiency: NAVA versus PSV
BACKGROUND Prolonged controlled mechanical ventilation depresses diaphragmatic efficiency. Assisted modes of ventilation should improve it. We assessed the impact of pressure support ventilation versus neurally adjusted ventilator assist on diaphragmatic efficiency. METHOD Patients previously ventilated with controlled mechanical ventilation for 72 hours or more were randomized to be ventilat...
متن کامل0449. Surface EMG of extra-diaphragmatic muscles can assess muscle unloading during neurally adjusted ventilatory support
Introduction Neurally adjusted ventilatory assist (NAVA) is used to adapt mechanical ventilation to patient demand while unloading respiratory muscles. Titration methods are focused on sustained unloading of the diaphragm while maintaining a stable tidal volume [1]. It is hypothesized that the activity of accessory respiratory muscles can supply extra information about muscle unloading and pati...
متن کاملNeurally adjusted ventilatory assist in critically ill postoperative patients: a crossover randomized study.
BACKGROUND Neurally adjusted ventilatory assist (NAVA) is a new mode of mechanical ventilation that delivers ventilatory assist in proportion to the electrical activity of the diaphragm. This study aimed to compare the ventilatory and gas exchange effects between NAVA and pressure support ventilation (PSV) during the weaning phase of critically ill patients who required mechanical ventilation s...
متن کاملEffect of ventilatory variability on occurrence of central apneas.
OBJECTIVE To compare the influence of 2 ventilation strategies on the occurrence of central apneas. METHODS This was a prospective, comparative, crossover study with 14 unsedated subjects undergoing weaning from mechanical ventilation in the medical ICU of Hôpital du Sacré-Cœur, Montréal, Québec, Canada. The subjects were ventilated alternately in neurally adjusted ventilatory assist (NAVA) a...
متن کاملInitiation of the Neurally Adjusted Ventilatory Assist Mode in the Neonatal Period in Iran
Abstract: The new neonatal ventilation methods have been developed along with utilization of new technological tools.This device is synchronized with the patient’s respiratory efforts. The ideal synchronized breath needs to be synchronous with initiation, size, and termination of the breath without delay in detecting of initial resiratory effort by device .The synchrony of respiration contribut...
متن کامل