Atomic emission method for total boron in blood during neutron-capture therapy.
نویسندگان
چکیده
BACKGROUND Boron neutron-capture therapy (BNCT) is a drug-targeted binary radiotherapy for cancer. The (10)B capture of thermal neutrons induces secondary radiation within cells during irradiation. The most widely used boron carrier is 4-dihydroxyborylphenylalanine (BPA). The duration and timing of the irradiation is adjusted by monitoring (10)B concentrations in whole blood. METHODS We developed a new method for boron determination that uses inductively coupled plasma atomic emission spectrometry (ICP-AES) and protein removal with trichloroacetic acid before analysis. This method was compared with the established but tedious inductively coupled plasma mass spectrometry (ICP-MS), which uses wet ashing as sample pretreatment. Erythrocyte boron concentrations were determined indirectly on the basis of plasma and whole blood boron concentrations and the hematocrit. The hematocrit was determined indirectly by measuring calcium concentrations in plasma and whole blood. RESULTS Within- and between-day CVs were <5%. The recoveries for boron in whole blood were 95.6-96.2%. A strong correlation was found between results of the ICP-AES and ICP-MS (r = 0.994). Marked differences in plasma and erythrocyte boron concentrations were observed during and after infusion of BPA fructose complex. CONCLUSIONS The present method is feasible, accurate, and one of the fastest for boron determination during BNCT. Our results indicate that it is preferable to determine boron in plasma and in whole blood. Indirect erythrocyte-boron determination thus becomes possible and avoids the impact of preanalytical confounding factors, such as the influence of the hematocrit of the patient. Such an approach enables a more reliable estimation of the irradiation dose.
منابع مشابه
A Monte Carlo study of SPECT in boron neutron capture therapy for a heterogeneous human phantom
Background: Boron neutron capture therapy (BNCT) is a binary radiotherapy combining biochemical targeting with neutron irradiation. However, monitoring the boron distribution is a fundamental problem in BNCT. Prompt gamma rays emitted by boron capture reaction can be used to address the issue. Materials and Methods: The general-purpose Monte Carlo toolkits Geant4 and MCNP were used for the simu...
متن کامل10B Concentration, Phantom Size and Tumor Location Dependent Dose Enhancement and Neutron Spectra in Boron Neutron Capture Therapy
Background: The amount of average dose enhancement in tumor loaded with 10B may vary due to various factors in boron neutron capture therapy.Objective: This study aims to evaluate dose enhancement in tumor loaded with 10B under influence of various factors and investigate the dependence of this dose enhancement on neutron spectra changes.Material and Methods: In this simulation stud...
متن کاملDesign and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy
Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...
متن کاملPlant-Based Calcium Fructoborate as Boron-Carrying Nanoparticles for Neutron Cancer Therapy
Boron neutron capture therapy (BNCT) is an effective clinical method in cancer treatment based on fission reactions and nuclear capturing. In this method, use of the best boron-containing agents for boron therapy and boron delivery agent for transfer to the infectious site are the key points for efficienct treatment. Our research indicated that calcium fructoborate(CF) was the best compound as...
متن کاملAn investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy
Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 47 10 شماره
صفحات -
تاریخ انتشار 2001