An Ethanol-Based Proliposome Technology for Enhanced Delivery and Improved “Respirability” of Antiasthma Aerosols Generated Using a Micropump Vibrating-Mesh Nebulizer
نویسندگان
چکیده
Salbutamol sulphate liposomes were generated using ethanolbased proliposomes followed by nebulization using an Aeroneb Pro vibrating-mesh nebulizer. The droplet size, output and fine particle fraction (FPF) of the drug incorporated in liposome formulation were compared to those of a conventional drug solution. Aerosol output was determined gravimetrically and drug output was analyzed by using high performance liquid chromatography. The potential of aerosol deposition in deep lung was evaluated using inertial impaction and laser diffraction. The effect of formulation surface tension on the aerosol performance was studied. Output and FPF were improved using liposomes compared to the conventional solution, for instance, FPF values were 57.85% and 45.81% respectively. The volume median diameter as measured by laser diffraction was respectively 3.44 μm and 3.22 μm; however, the higher FPF of the liposome formulation is justified by the lower polydispersity of its aerosol. The improved aerosol performance using liposomes was attributed to the reduction of surface tension caused by the presence of phospholipid. This is the first study that demons trates the ability of liposomes to improve the nebulized drug output and FPF.
منابع مشابه
Characterization of Ribavirin Aerosol With Small Particle Aerosol Generator and Vibrating Mesh Micropump Aerosol Technologies.
BACKGROUND Ribavirin is an antiviral drug that can be administered by inhalation. Despite advancements in the oral delivery of this medication, there has been a renewed interested in delivering ribavirin via the pulmonary system. Although data are not conclusive that inhaled ribavirin improves outcomes, we set out to determine whether delivery by a newer generation nebulizer, the vibrating mesh...
متن کاملEffect of Aerosol Devices and Administration Techniques on Drug Delivery in a Simulated Spontaneously Breathing Pediatric Tracheostomy Model.
BACKGROUND This study was conducted to compare the efficiency of jet nebulizers, vibrating mesh nebulizers, and pressurized metered-dose inhalers (pMDI) during assisted and unassisted administration techniques using a simulated spontaneously breathing pediatric model with a tracheostomy tube (TT). METHODS An in vitro breathing model consisting of an uncuffed TT (4.5-mm inner diameter) was att...
متن کاملPhysicochemical aspects and efficiency of albuterol nebulization: comparison of three aerosol types in an in vitro pediatric model.
BACKGROUND Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METH...
متن کاملIn Vitro Evaluation of Aerosols Delivered via the Nasal Route.
BACKGROUND Infants and young children are obligate nose breathers; therefore, a transnasal route seems the logical delivery method of inhaled aerosols. The efficiency of aerosol delivery depends on several factors, such as interface, type of nebulizer, and patient age and breathing pattern. We hypothesized that the use of a vibrating mesh nebulizer, a tight-fitting face mask, and a head model a...
متن کاملAlbuterol delivery by 4 different nebulizers placed in 4 different positions in a pediatric ventilator in vitro model.
BACKGROUND The type of aerosol generator and the position in the ventilator circuit are crucial to determine aerosol delivery during mechanical ventilation. We compared lung deposition of albuterol aerosols generated by 4 different nebulizers placed in-line in 4 different positions in a pediatric ventilator model. METHODS Two brands of continuously operated jet nebulizer (6 L/ min, oxygen), a...
متن کامل