Comparison Between NIST and AF Laser Energy Standards Using High Power Lasers

نویسندگان

  • Xiaoyu Li
  • Thomas Scott (Retired)
  • Chris Cromer
  • David Cooper
  • Steven Comisford
چکیده

We report the results of a high-energy laser calorimeter comparison conducted by the National Institute of Standards and Technology (NIST), Boulder, Colorado and the U.S. Air Force Primary Standards laboratory (AFPSL), Heath, Ohio. A laser power meter, used as a transfer standard, was calibrated at each laboratory, sequentially, and the measurement results were compared. These measurements were performed at a nominal power of 800 W and a wavelength of 10.6 μm using CO2 lasers. Excellent measurement agreement (1.02 %) was demonstrated, which was well within each of the expanded uncertainties from the two laboratories involved in this comparison.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reflective Optical Chopper Used in NIST High-Power Laser Measurements

For the past ten years, NIST has used high-reflectivity, optical choppers as beamsplitters and attenuators when calibrating the absolute responsivity and response linearity of detectors used with high-power CW lasers. The chopper-based technique has several advantages over the use of wedge-shaped transparent materials (usually crystals) often used as beam splitters in this type of measurement s...

متن کامل

High Intensity Lasers in Periodontics: A Review

Background and Aim: Lasers can serve as a new powerful tool in dentistry. High intensity laser therapy is becoming the treatment of choice compared with conventional periodontal therapy due to accurate incision and soft and hard tissue ablation, hemostasis, reduction of postoperative pain and infection, optimal debridement, and enhanced healing. Although high intensity laser therapy assumes to ...

متن کامل

Power Supply and Current Modulation Circuits for Semiconductor Lasers

Design and construction of a stable current supply with protection circuits are described. The reported circuit provides a high-stable and high-level current variable from 0.5-1.2 A with the protect ion circuits to prevent over load current, voltage and off-range temperature operation. A detailed analysis of the circuit parameters is given and the time behaviors of the load voltage/current and ...

متن کامل

Nonlinearity Measurements of High-Power Laser Detectors at NIST

We briefly explain the fundamentals of detector nonlinearity applicable to both electrical and optical nonlinearity measurements. We specifically discuss the attenuation method for optical nonlinearity measurement that the NIST system is based upon, and we review the possible sources of nonlinearity inherent to thermal detectors used with high-power lasers. We also describe, in detail, the NIST...

متن کامل

Comparison of Soft Tissue Thermal Changes Induced by Three Types of Diode Lasers at 810, 940, and 980nm Wavelengths

Background and Aim: Diode laser is a great choice for soft tissue surgery. The diode laser is partially absorbed by hard dental tissues, making it safe for soft tissue surgery. This study aimed to compare the tissue thermal changes induced by three types of diode lasers at 810, 940, and 980nm wavelengths. Materials and Methods: In this in-vitro experimental study, using a diode laser device (c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 112  شماره 

صفحات  -

تاریخ انتشار 2007