A Study on Portal Image for the Automatic Verification of Radiation Therapy
نویسندگان
چکیده
In this paper, near real time digital radiography system was implemented for the automatic verification of local errors between simulation plan and radiation therapy. Portal image could be acquired through video camera, image board and PC after therapy radiation was converted into light by a metal/fluorescent screen. Considering the divergence according to the distance between the source and the plate, we made a 340 × 340 × 12 cm3 basis point plate on which five rods of 4 cm height and 8mm diameter lead (Pb) were built to display reference points on the simulator and the portal image. We converted the portal image into the binary image using the optimal threshold value which was gotten through the histogram analysis of the acquired portal image using the basis point plate. we got the location information of the iso-center and basis points from the binary image, and removed the systematic errors which were from the differences between the simulation plan and the portal image. Field size which was measured automatically by optimal threshold portal image, was verified with simulation plan. Anatomic errors were automatically detected and verified with the normalized simulation and the portal image by pattern matching method after irradiating a part of the radiation. Therapy efficiency was improved and radiation side effects were reduced by these techniques, so exact radiation treatment are expected. key words: portal image, digital radiography, local error, automatic verification, pattern matching method, basis point plate
منابع مشابه
Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy
Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...
متن کاملComparative Study between Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) for Radiation Treatment Verifications
Introduction: Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) are the preferred tools of Image Guided Radiotherapy (IGRT) and Dose Guided Radiotherapy (DGRT) which have been used for Radiotherapy treatment verifications. As a result, the number of publications dealing with these two tools for radiation treatment verification has increased consi...
متن کاملA quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes
Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...
متن کاملPretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)
Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...
متن کاملDetermination of geometric accuracy of radiotherapy fields by port film and DRR using Matlab Graphical User Interface
Introduction: Radiation therapy is one of the methods of cancer treatment. In this method, it is necessary to avoid harming the healthy tissues of the patient which is in the vicinity of the target, as much as possible. Treatment verification is one of the most important steps of radiation therapy which has two usual methods, using Port film and EPID. The accuracy and precision of treatment in ...
متن کامل