Monolithic silica-based capillary reversed-phase liquid chromatography/electrospray mass spectrometry for plant metabolomics.

نویسندگان

  • Vladimir V Tolstikov
  • Arjen Lommen
  • Kazuki Nakanishi
  • Nobuo Tanaka
  • Oliver Fiehn
چکیده

Application of C18 monolithic silica capillary columns in HPLC coupled to ion trap mass spectrometry detection was studied for probing the metabolome of the model plant Arabidopsis thaliana. It could be shown that the use of a long capillary column is an easy and effective approach to reduce ionization suppression by enhanced chromatographic resolution. Several hundred peaks could be detected using a 90-cm capillary column for LC separation and a noise reduction and automatic peak alignment software, which outperformed manual inspection or commercially available mass spectral deconvolution software.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Linking protein fractionation with multidimensional monolithic reversed-phase peptide chromatography/mass spectrometry enhances protein identification from complex mixtures even in the presence of abundant proteins.

Recently, multidimensional shotgun proteomics has proven to be an alternative technology able to identify hundreds of proteins from single samples. Two major limitations of the technology are the presence of high abundance proteins (e.g. RUBISCO in plant leaf tissue) and the enormous number of co-eluting peptides that overstrain the loading and resolving capacity of conventional particle-packed...

متن کامل

Highly efficient analysis of underivatized carbohydrates using monolithic-silica-based capillary hydrophilic interaction (HILIC) HPLC.

A polyacrylamide (PAAm)-modified monolithic silica capillary column of increased phase ratio, 200T-PAAm, for hydrophilic interaction liquid chromatography (HILIC) was prepared. The column showed high separation efficiency, with a theoretical plate height H = 7-20 microm at a linear velocity, u = 1-7 mm/s. From a kinetic plot analysis, it was expected that the monolithic column could provide thr...

متن کامل

Rapid protein digestion and identification using monolithic enzymatic microreactor coupled with nano-liquid chromatography-electrospray ionization mass spectrometry.

A novel monolithic enzymatic microreactor was prepared in the fused-silica capillary by in situ polymerization of acrylamide (AA), N-acryloxysuccinimide (NAS) and ethylene dimethacrylate (EDMA) in the presence of a binary porogenic mixture of dodecanol and cyclohexanol, which could offer very low back pressure, enabling the fast digestion of proteins. The performance of the monolithic microreac...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 75 23  شماره 

صفحات  -

تاریخ انتشار 2003