Thermal modeling and experimental validation of human hair and skin heated by broadband light.

نویسندگان

  • Feng Sun
  • Alex Chaney
  • Robert Anderson
  • Guillermo Aguilar
چکیده

BACKGROUND AND OBJECTIVE In recent years, selective photothermolysis (PT) based on broadband light and assisted by skin vacuum (Photopneumatic Technology or PPx, by Aesthera) was introduced into the aesthetic market for epilation (hair removal) procedures. The present study aims to: (a) determine the overall effect of PPx on skin humidity and associated skin optical properties, and; (b) develop a PT numerical model to study the spatial and temporal hair and skin temperature variations during PPx epilation. METHODS A customized cup was used to apply moderate vacuum for 10 seconds on the forearms and faces of five volunteers. Skin humidity was measured on test sites immediately after vacuum application. A selective PT model was developed and used to simulate transport of photons from a broadband light source into human skin. The PT model is experimentally validated using agar gel tissue phantoms. Systematic numerical simulations are carried out for fluences varying from 5.0 to 7.0 J/cm(2) and pulse durations varying from 2.5 to 25 milliseconds. RESULTS Results of in vivo skin surface humidity measurements reveal that while absolute humidity varies between 30% and 75% between different volunteers and different locations, vacuum has a minimal effect on it. Experimental measurements of temperature variation during and after broadband light treatment agree well with model predictions. Numerical results indicate that average hair follicle temperature increases as a linear function of fluence. Longer pulse duration results in lower follicle temperature. However, immediately after each pulse, the temperature distribution within the hair follicle is highly non-uniform: the minimum temperature occurs at the follicle edge while the maximum is located between the center and edge of the follicle. CONCLUSIONS Vacuum appears to have minimal effect on skin humidity. The PT model developed and validated is expected to assist clinicians in the selection of broadband light treatment parameters to achieve optimal therapeutic outcomes during epilation procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Possibility of Early Detection of Bovine Mastitis in Dairy Cows Using Thermal Images Processing

Bovine mastitis (BM) is a prevalent condition on dairy farms, affecting both livestock health and reducing profitability. This study investigated the feasibility of diagnosing BM in Holstein dairy cattle using thermography. To increase the detection between healthy cattle and unhealthy one and to better compare the results from thermal images, a number of parameters including somatic cell count...

متن کامل

Numerical Modeling of the Shear Module of Alginate Micro-Beads under the Ultrasonic Thermal Effect

The mechanical properties of microscopic particles have been a heated research object for it takes the deformation of micro-beads in the microfluidic environment into account. Sufficient knowledge on mechanical properties of micro-beads would lead to better device design and application for cell mechanics, tissue engineering, etc. The physical properties of alginate beads were examined both in ...

متن کامل

Induction-heated Tool Machining of Elastomers—part 1: Finite Difference Thermal Modeling and Experimental Validation

& Experiments and finite difference thermal modeling of the induction-heated tool for end milling of elastomers are investigated. Three sets of experiments are designed to calibrate the contact thermocouple for the tool tip temperature measurement, study the effect of tool rotational speed on induction heat generation and convective heat transfer, and measure the tool temperature distribution f...

متن کامل

Investigation of combined effects of noise and low air temperature on human-environmental comfort and physiological responses- An experimental study

Background and Aim: Combined exposure to noise and temperature can affect the neurophysiological responses of the office staff. The present study was done to investigate the impacts of combined exposure to noise and low air temperature on physiological responses and environmental comfort. Methods: In this experimental study, the studied population included the students who were randomly selecte...

متن کامل

Efficacy of the intense pulsed light source on unwanted hairs

Background: The need for a rapid, non-invasive method for unwanted hair removal has led to the development of various light sources for this purpose. Objective: To evaluate the efficacy of Intense Pulsed Light Source (IPLS) on unwanted hairs. Patients and Methods: In this open, uncontrolled clinical trial, 77 different anatomical areas in 34 referred patients to “Novin Didegan Clinic” in Tehran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lasers in surgery and medicine

دوره 41 2  شماره 

صفحات  -

تاریخ انتشار 2009