چکیده

BACKGROUND There is growing evidence from the literature that right anterior minithoracotomy aortic valve replacement (RAT-AVR) improves clinical outcome. However, increased cross clamp time is the strongest argument for surgeons not performing RAT-AVR. Rapid deployment aortic valve systems have the potential to decrease cross-clamp time and ease this procedure. We assessed clinical outcome of rapid deployment and conventional valves through RAT. METHODS Sixty-eight patients (mean age 76 ± 6 years, 32% females) underwent RAT-AVR between 9/2013 and 7/2015. According to the valve type implanted the patients were divided into two groups. In 43 patients (R-group; mean age 74.1 ± 6.6 years) a rapid deployment valve system (Edwards Intuity, Edwards Lifesciences Corp; Irvine, Calif) and in 25 patients (C-group; mean age 74.2 ± 6.6 years) a conventional stented biological aortic valve was implanted. RESULTS Aortic cross-clamp (42.1 ± 12 min vs. 68.3 ± 20.3 min; p < 0.001) and bypass time (80.4 ± 39.3 min vs. 106.6 ± 23.2 min; p = 0.001) were shorter in the rapid deployment group (R-group). We observed no differences in clinical outcome. Postoperative gradients (R-group: max gradient, 14.3 ± 8 mmHg vs. 15.5 ± 5 mmHg (C-group), mean gradient, 9.2 ± 1.7 mmHg (R-group) vs. 9.1 ± 2.3 mmHg (C-group) revealed no differences. However, larger prostheses were implanted in C-group (25 mm; IQR 23-27 mm vs. 23 mm; IQR 21-25; p = 0.009). CONCLUSIONS Our data suggest that the rapid deployment aortic valve system reduced cross clamp and bypass time in patients undergoing RAT-AVR with similar hemodynamics as with larger size stented prosthesis. However, larger studies and long-term follow-up are mandatory to confirm our findings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimally invasive aortic valve surgery: state of the art and future directions.

Minimally invasive aortic valve replacement (MIAVR) is defined as an aortic valve replacement (AVR) procedure that involves a small chest wall incision as opposed to conventional full sternotomy (FS). The MIAVR approach is increasingly being used with the aim of reducing the "invasiveness" of the surgical procedure, while maintaining the same efficacy, quality and safety of a conventional appro...

متن کامل

Minimally invasive aortic valve replacement: an alternative to the conventional technique.

OBJECTIVES To demonstrate the use of minimally invasive surgery for aortic valve replacement and compare your results with the traditional method. METHODS Between 2006 and 2011 sixty patients underwent surgery on aortic valve, after written consent, these 40 by minimally invasive technique with right anterior minithoracotomy access (Group 1/G1) and 20 by median sternotomy (Group 2/G2). Compar...

متن کامل

Right anterior minithoracotomy for aortic valve replacement.

We present the case of a 78-year-old lady with severe aortic stenosis who underwent cardiovascular investigations for ingravescent dyspnea [New York Heart Association (NYHA) functional class III] undergoing minimally invasive aortic valve replacement (MIAVR) through right anterior minithoracotomy (RT). The patient’s height and weight were 170 cm and 62 kg, respectively. Risk factors included hy...

متن کامل

eComment: Aortic valve replacement in patients with patent coronary grafts: how to do it?

Partial upper re-sternotomy for aortic valve replacement or re-replacement after previous cardiac surgery. Aortic valve surgery after previous coronary artery bypass grafting with functioning internal mammary artery grafts. Do you need to clamp a patent left internal thoracic artery left anterior descending graft in reoperative cardiac surgery? Ann Thorac Surg 2009;87:742–747. w9x Sutherland FW...

متن کامل

Aortic valve replacement with a rapid deployment Edwards Intuity bioprosthesis using a completely video-guided approach.

We describe the case of a 54-year-old female with severe aortic stenosis and a background of severe comorbidities including prior radiotherapy for Hodgkin’s lymphoma, splenectomy, severe chronic obstructive pulmonary disease, scleroderma with laryngeal and esophageal involvement, and systemic and pulmonary hypertension. The patient underwent totally video-guided aortic valve replacement through...