Proton MR spectroscopic imaging without water suppression.
نویسندگان
چکیده
To improve reproducibility in proton magnetic resonance (MR) spectroscopic imaging in human brain, simultaneous acquisition of the internal water reference and metabolite signals was evaluated. Measurements in healthy volunteers showed that the increase in dynamic range from signal oversampling was sufficient to avoid digitization errors. In addition, use of singular value decomposition techniques and finite impulse response filters proved effective in separating water and metabolite signals and providing estimates of the metabolite concentrations.
منابع مشابه
Proton MR Spectroscopy Using Short TE PRESS without Water Suppression. In Vivo Application to Rat Brain at 7 Tesla
Introduction: Although several approaches have been described to avoid water suppression (WS) in localized proton MR spectroscopy (MRS) and spectroscopic imaging (SI) [1-9], WS is still a standard procedure for H MRS and SI. However, if WS may be omitted without compromising the spectrum quality, the simultaneously acquired water signal can be used for correction procedures (line shape and phas...
متن کاملAutomatic placement of outer volume suppression slices in MR spectroscopic imaging of the human brain.
Spatial suppression of peripheral regions (outer volume suppression) is used in MR spectroscopic imaging to reduce contamination from strong lipid and water signals. The manual placement of outer volume suppression slices requires significant operator interaction, which is time consuming and introduces variability in volume coverage. Placing a large number of outer volume saturation bands for v...
متن کاملEffects of Contrast Agent and Outer Volume Saturation Bands on Water Suppression and Shimming of Hepatic Single-Volume Proton MR Spectroscopy at 3.0T
PURPOSE To determine whether administration of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) and whether placement of the outer volume saturation bands significantly affect shimming and water suppression on hepatic MR spectroscopic prescanning. METHOD Region of interest (ROI) of 2 cm × 2 cm × 2 cm was carefully positioned in the region of the middle portion of the right hepatic lob...
متن کاملAtlas-based automated positioning of outer volume suppression slices in short-echo time 3D MR spectroscopic imaging of the human brain.
Spatial suppression of peripheral lipid-containing regions in volumetric MR spectroscopic imaging of the human brain requires placing large numbers of outer volume suppression (OVS) slices, which is time-consuming, prone to operator error and may introduce subject-dependent variability in volume coverage. We developed a novel, computationally efficient atlas-based approach for automated positio...
متن کاملNavigator gated and cardiac triggered echo-planar spectroscopic imaging of the heart
Fig. 3: Short-axis view a), image of the water resonance of the unsuppressed EPSI reference b), single average proton spectrum with the triglyceride (TG) resonance from the septal wall (marked voxel in b) c) and corresponding spectrum from 8 signal averages showing creatine (Cr) at 3.03 ppm d). Figure 2: Cardiac field map computed from an EPSI scan acquired without water suppression a). The sum...