Comparison between Readout-Segmented (RS)-EPI and an improved distortion correction method for Short-Axis Propeller (SAP)-EPI

نویسندگان

  • S. Skare
  • S. J. Holdsworth
  • K. Yeom
  • P. D. Barnes
چکیده

252x252 (left) and 384x384 (right). SAP-EPI and RS-EPI datasets were acquired in equivalent scan times of 1:24min/volume. Fig 3: (a) Scan-timenormalized noise maps (i.e. accounting for the maximum number of slices) of distortion-correctedSAP-EPI and RS-EPI calculated over six b = 0 scans (matrix size=384). (b) A RSEPI 384 image is blurred by a Gaussian kernel to achieve the same SNR as SAPEPI, resulting in a loss of resolution. This shows that distortioncorrected SAP-EPI has better scan efficiency than RS-EPI even at high resolutions. Comparison between Readout-Segmented (RS)-EPI and an improved distortion correction method for Short-Axis Propeller (SAP)-EPI

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusion-Weighted Imaging of the Abdomen with Readout-Segmented (RS)-EPI

Introduction: Diffusion-weighted imaging (DWI) in the abdomen has proven useful for various pathologies, including liver lesion characterization [1-4] and simple vessel suppression, diagnosis of diffuse renal disease [5-8], and detection of metastatic spread to lymph nodes [9,10]. However, image distortions arising from the use of EPI has shown to be problematic. We have recently applied DW ‘Sh...

متن کامل

Diffusion weighted image domain Propeller EPI (DW iProp EPI)

Introduction Geometric distortions in Echo Planar Imaging (EPI) are dependent on two sequence parameters: the phase encoding FOV and the echo spacing between two consecutive ky lines, both of which affect the k-space traversal speed. Assuming that a maximum readout gradient bandwidth is used, the echo spacing can be reduced by decreasing the resolution in the kx (not ky!) direction. Both Short ...

متن کامل

b-Matrix Correction Applied to High Resolution DTI

INTRODUCTION – High resolution Diffusion Tensor Imaging (DTI) has been challenging for several reasons. Perhaps the major obstacle is due to the random phase effects that change between successive shots and pixel-by-pixel misregistration caused by patient motion. In addition, DTI images acquired with EPI are typically hampered by geometric distortion, blurring, and – in the case of multi-shot E...

متن کامل

T1-weighted 3D SAP-EPI for use in pediatric imaging without general anesthesia

Introduction: 3D Short-Axis readout Propeller EPI (SAP-EPI) was recently introduced as an alternative to the 3D T1-w Spoiled Gradient Echo (SPGR) technique commonly used for routine clinical studies [1]. In the presence of motion, the data consistency for encoding in 3D-SPGR is violated and gives rise to ghosting artifacts. In 3D SAP-EPI, the acquisition of ‘bricks’ (each consisting of an EPI b...

متن کامل

GRAPPA-accelerated short axis BLADE EPI for multi-shot diffusion weighted imaging

Introduction: Artifacts in diffusion weighted EPI (DW-EPI) can be significantly reduced by increasing the speed with which k-space is traversed along the phaseencoding (PE) direction. The traverse speed can be increased through parallel acquisition techniques (PAT) [1] and by shortening the time between two successive samples in the PE direction (echo spacing ES). ES can be decreased through th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009