Seismic Behavior of One-Storey Gabion-Box Walls Buildings
نویسندگان
چکیده
Gabion-boxes, made with steel wire mesh and filled with stones of appropriated size, are normally stacked up one into another to form a retaining wall. Given their reduced costs and the easy availability of their constituting materials, gabion-box walls have been extensively used in developing countries (such as Nepal) also to realize simple one-storey residential buildings. In recent years, many of these structures have been subjected to several strong earthquakes and have shown a good seismic behavior, even if they have never been the object of a proper structural design. In the scientific literature, research studies have been developed on gabion-box walls used as retaining systems, but no investigations have been conducted on the performances of gabion-box walls buildings. In this respect, the general objective of this research work is to give a first insight into the static and seismic behavior of such gabion-box walls buildings through analytical considerations and numerical models. In detail, with reference to a typical 5m×5m plan model, this article investigates the in-plane and out-of-plane seismic responses of its constituting walls, by means of simple analytical interpretations and Discrete Element Method numerical simulations. Even if this study should be considered as a starting point and even if the fundamental cellular behavior of the three-dimensional structure has not been fully taken into account, some criticalities have been disclosed and the order of magnitude of the seismic activation load multipliers has been estimated. The out-ofplane collapse mechanism is characterized by multiplier around 0.15, while the in-plane mechanism multiplier depends on the position of the door in the single wall (0.10–0.20), but it can be easily increased with lintel beams placement. The results are based on the assumptions taken by several authors and have not been verified with experimental tests. Nevertheless, some practical suggestions (basically in terms of spacing and construction details, such as vertical connectors and reinforcing steel knots) can be derived to improve the construction in order to ensure a better seismic behavior.
منابع مشابه
Reliability-based Seismic Assessment of Asymetric Multi-storey Buildings with Rc Shear Walls
The performance of buildings subjected to earthquake loads has shown that asymmetric structures are caused more extensive damages in comparison with symmetric structures. Hence, the seismic performance of asymmetric structures should be assessed due to future random earthquakes. Reliability-based seismic assessment as one of the tools in performance-based earthquake engineering has been introdu...
متن کاملFree-Standing Gabion Walls in Seismic Regions
This thesis investigates the behavior of free-standing gabion walls in areas of mild seismicity. To investigate this behavior, three walls of varying internal cable patterns were constructed at a quarter-scale. These walls were tested with a mass shaker, and mode shapes, tone extractions, and damping ratios were calculated. A modal analysis was conducted using design spectra created from a suit...
متن کاملSeismic Design of Box-Type Unreinforced Masonry Buildings Through Direct Displacement-Based Approach
In the last decade, displacement-based seismic design procedures have been recognised to be effective alternatives to force-based design (FBD) methods. Indeed, displacement based design (DBD) may allow the structural engineer to get more realistic predictions of local and global deformations of the structure, and hence damage, under design earthquakes. This facilitates the achievement of perfor...
متن کاملInfluence of initial spatial layout on seismic behavior of masonry buildings with curved roof systems
Early design decisions made on building configuration and spatial design affect seismic behavior of buildings. Therefore introducing design guidelines and empirical methods implemented to assess seismic behavior of buildings have been proposed as an appropriate approach. Such concept helps architects to take into the consideration that how their preliminary design decisions influence downstream...
متن کاملInfluence of Masonry Infills Walls on the Seismic Behaviour of Multi-storey Waffle Slabs Rc Buildings
In this work, we analyze the influence of masonry infill walls on the seismic performance of waffle slabs reinforced concrete (RC) framed structures. We analyze buildings of three, five and eight storeys, which are representative for a big number of housings in Barcelona, Spain. Capacity spectra have been obtained by performing pushover analyses and we have used a simplified procedure to obtain...
متن کامل