Beam Position Monitor Test Stand

نویسنده

  • Christopher D. Chan
چکیده

The need to produce intense X-rays in the Energy Recovery Linear Accelerator requires shorter and narrower electron beams than the Cornell Electron Storage Ring can provide. Such electron beams will demand highly accurate beam position monitors (BPMs) to enable operators to control the beam. To prepare for new BPMs, a test stand has been built to conduct experiments on new algorithms and designs. This paper discusses this test stand.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of the Beam-Position Monitor System for the SLAC PEP-II B Factory

The Beam-Position Monitors (BPM) for the PEP-II B Factory consist of four 1.5cm diameter button style pickups mounted on the diagonals of the quadrupole vacuum chambers. Before installation of the vacuum chambers in the quadrupole assemblies, the electrical center of the BPMs is measured with respect to the mechanical center in a calibration test stand. In this paper the calibrations test stand...

متن کامل

Calibration of the Beam-position Monitor System for the Slac Pep-i1 B Factory

The Beam-Position Monitors (BPM) for the PEP-11 B Factory consist of four 1.5cm diameter button style pickups mounted on the diagonals of the quadrupole vacuum chambers. Before installation of the vacuum chambers in the quadrupole assemblies, the electrical center of the BPMs is measured with respect to the mechanical center in a calibration test stand. In this paper the calibrations test stand...

متن کامل

A Stand - Alone Beam Steering and Profile Monitor

A system has been developed, the primary function of which is to continually display the position, shape, and intensity of the charged particle beam being delivered to the experiment. The system is modular for easy maintenance and is a stand-alone device independent of any computer.

متن کامل

New Microwave Beam Position Monitors for the TESLA Test Facility | FEL

Beam-based alignment is essential for the operation of the SASE-FEL at the TESLA Test Facility Linac. In order to ensure the overlap of the photon beam and the electron beam, the position of the electron beam has to be measured along the undulator beamline with a high resolution. Due to the severe space limitations, a new microwave concept is being considered. It is based on special ridged wave...

متن کامل

A beam monitor using silicon pixel sensors for hadron therapy

We report the design and test results of a beam monitor developed for online monitoring in hadron therapy. The beam monitor uses eight silicon pixel sensors, Topmetal-II−, as the anode array. Topmetal-II− is a charge sensor designed in a CMOS 0.35 μm technology. Each Topmetal-II− sensor has 72 × 72 pixels and the pixel size is 83 × 83 μm. In our design, the beam passes through the beam monitor ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004