Radiation damage in protein crystals is reduced with a micron-sized X-ray beam.

نویسندگان

  • Ruslan Sanishvili
  • Derek W Yoder
  • Sudhir Babu Pothineni
  • Gerd Rosenbaum
  • Shenglan Xu
  • Stefan Vogt
  • Sergey Stepanov
  • Oleg A Makarov
  • Stephen Corcoran
  • Richard Benn
  • Venugopalan Nagarajan
  • Janet L Smith
  • Robert F Fischetti
چکیده

Radiation damage is a major limitation in crystallography of biological macromolecules, even for cryocooled samples, and is particularly acute in microdiffraction. For the X-ray energies most commonly used for protein crystallography at synchrotron sources, photoelectrons are the predominant source of radiation damage. If the beam size is small relative to the photoelectron path length, then the photoelectron may escape the beam footprint, resulting in less damage in the illuminated volume. Thus, it may be possible to exploit this phenomenon to reduce radiation-induced damage during data measurement for techniques such as diffraction, spectroscopy, and imaging that use X-rays to probe both crystalline and noncrystalline biological samples. In a systematic and direct experimental demonstration of reduced radiation damage in protein crystals with small beams, damage was measured as a function of micron-sized X-ray beams of decreasing dimensions. The damage rate normalized for dose was reduced by a factor of three from the largest (15.6 μm) to the smallest (0.84 μm) X-ray beam used. Radiation-induced damage to protein crystals was also mapped parallel and perpendicular to the polarization direction of an incident 1-μm X-ray beam. Damage was greatest at the beam center and decreased monotonically to zero at a distance of about 4 μm, establishing the range of photoelectrons. The observed damage is less anisotropic than photoelectron emission probability, consistent with photoelectron trajectory simulations. These experimental results provide the basis for data collection protocols to mitigate with micron-sized X-ray beams the effects of radiation damage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation damage in a micron-sized protein crystal studied via reciprocal space mapping and Bragg coherent diffractive imaging

For laboratory and synchrotron based X-ray sources, radiation damage has posed a significant barrier to obtaining high-resolution structural data from biological macromolecules. The problem is particularly acute for micron-sized crystals where the weaker signal often necessitates the use of higher intensity beams to obtain the relevant data. Here, we employ a combination of techniques, includin...

متن کامل

Perfect Crystals in the Asymmetric Bragg Geometry as Optical Elements for Coherent X-ray Beams.

Perfect crystals in the asymmetric Bragg geometry are evaluated as optical elements for manipulating coherent X-ray beams. Such optics can be used to modify the transverse coherence length of a synchrotron X-ray beam, with the intention of increasing the usable coherent flux. The wavelength range, angular divergence and flux of X-rays passing through a pinhole aperture are examined in detail, a...

متن کامل

Serial crystallography on in vivo grown microcrystals using synchrotron radiation

Crystal structure determinations of biological macromolecules are limited by the availability of sufficiently sized crystals and by the fact that crystal quality deteriorates during data collection owing to radiation damage. Exploiting a micrometre-sized X-ray beam, high-precision diffractometry and shutterless data acquisition with a pixel-array detector, a strategy for collecting data from ma...

متن کامل

A Medipix quantum area detector allows rotation electron diffraction data collection from submicrometre three-dimensional protein crystals

When protein crystals are submicrometre-sized, X-ray radiation damage precludes conventional diffraction data collection. For crystals that are of the order of 100 nm in size, at best only single-shot diffraction patterns can be collected and rotation data collection has not been possible, irrespective of the diffraction technique used. Here, it is shown that at a very low electron dose (at mos...

متن کامل

Matching X-ray source, optics and detectors to protein crystallography requirements.

A review of the requirements for collecting X-ray diffraction data from protein crystals is given, with an emphasis on the properties of the crystal and its diffraction pattern. The size, unit-cell dimensions and perfection of the crystals can all be related to the required size and divergence of the incident X-ray beam, together with the size and spatial resolution of the detector. The X-ray b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the National Academy of Sciences of the United States of America

دوره 108 15  شماره 

صفحات  -

تاریخ انتشار 2011