Accuracy and precision of cap thickness in small incision lenticule extraction

نویسندگان

  • Engin Bilge Ozgurhan
  • Alper Agca
  • Ercument Bozkurt
  • Baran Gencer
  • Ugur Celik
  • Kadir Ilker Cankaya
  • Ahmet Demirok
  • Omer Faruk Yilmaz
چکیده

AIMS To report and compare the cap thickness predictability of small incision lenticule extraction (SMILE) and flap thickness of femtosecond laser-assisted in situ keratomileusis (femto-LASIK). SETTINGS AND DESIGN Beyoglu Eye Training and Research Hospital, Refractive Surgery Department, Istanbul, Turkey. Retrospective pilot study. MATERIALS AND METHODS Medical records of patients who had SMILE in one eye and femto-LASIK in the other eye were reviewed. Visante corneal Optical Coherence Tomography (OCT) images at 1 week and 1 month post-surgery were analyzed. Both cap and flap thickness at the temporal edge and the nasal edge were measured and compared to each other. STATISTICAL ANALYSES USED: PAWS Statistics 18 and unpaired student t-test were used to compare the groups. RESULTS The study included 66 eyes of 33 patients (24.7 ± 3.8 years, 20 females and 13 males). Mean flap thickness was 114.88 μm ± 4.96 μm, and mean cap thickness was 114.63 μm ± 5.18 μm. In group 1 (SMILE), cap thickness values were 115.84 μm ± 6.84 μm, 114.75 μm ± 7.36 μm, 113.66 μm ± 6.88 μm, and 114.27 μm ± 6.90 μm in measurement zones 1, 2, 3, and 4, respectively. In group 2 (FemtoLASIK), flap corneal thickness values were 115.96 mmHg ± 7.01 mmHg, 114.72 mmHg ± 7.17 mmHg, 113.54 mmHg ± 6.45 mmHg, and 115.30 mmHg ± 6.64 mmHg in measurement zones 1, 2, 3, and 4, respectively. In both groups, no statistically significant change within the measurement zones was observed. CONCLUSION The predictability of cap thickness in SMILE surgery does not differ from the femto-LASIK flaps created using the same femtosecond laser platform.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy, safety, predictability, contrast sensitivity, and aberrations after femtosecond laser lenticule extraction.

PURPOSE To compare femtosecond lenticule extraction and small-incision lenticule extraction to treat moderate to high myopia. SETTING Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark. DESIGN Prospective clinical single-masked paired-eye study. METHODS An intrastromal lenticule was cut by a femtosecond laser and manually extracted. In femtosecond lenticule extractio...

متن کامل

Comparison of Two Cap Thickness in Small Incision Lenticule Extraction: 100μm versus 160μm

PURPOSE To compare the changes of biomechanical properties, endothelial cell density (ECD), and posterior corneal elevation (PCE) after femtosecond small incision lenticule extractions (SMILEs) with 100μm versus 160μm cap thicknesses. METHODS A total of 12 rabbits were randomly assigned into two groups of 6 each. SMILE was performed at a depth of either 160μm (160-cap group) or 100μm (100-cap...

متن کامل

Corneal biomechanical effects: small-incision lenticule extraction versus femtosecond laser-assisted laser in situ keratomileusis.

PURPOSE To compare the biomechanical properties of the cornea after small-incision lenticule extraction (lenticule extraction group) with those after femtosecond laser-assisted laser in situ keratomileusis (femtosecond LASIK group). SETTING Tianjin Eye Hospital & Eye Institute, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Medical University, Tianjin, China. DESIGN Pro...

متن کامل

Comparison of different intraocular pressure measurement techniques in normal eyes and post small incision lenticule extraction

PURPOSE The purpose of the study was to determine the accuracy of intraocular pressure (IOP) measurement after small incision lenticule extraction (SMILE) using Goldmann applanation tonometry (GAT) and ocular response analyzer (ORA). METHODS This is a prospective clinical study that was conducted on 30 eyes in the interval between February 2016 and September 2016. The age of the patients rang...

متن کامل

Comparison of femtosecond laser small-incision lenticule extraction and laser-assisted subepithelial keratectomy to correct myopic astigmatism.

PURPOSE To compare the efficacy of correcting myopic astigmatism with femtosecond laser small-incision lenticule extraction (SMILE, Carl Zeiss Meditec AG) versus laser-assisted subepithelial keratectomy (LASEK). SETTING The study was conducted at the Ophthalmology Department, Eye and ENT Hospital, Shanghai, China. DESIGN A retrospective, cross-sectional study. METHODS This study included ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013