Blood Detection in IVUS Images for 3D Volume of Lumen Changes Measurement Due to Different Drugs Administration
نویسندگان
چکیده
Lumen volume variations is of great interest by the physicians given it reduces the probability of infarction as it increases. In this paper we present a fast and efficient method to detect the lumen borders in longitudinal cuts of IVUS sequences using an AdaBoost classifier trained with several local features assuring their stability. We propose a criterion for feature selection based on stability leave-one-out cross validation. Results on the segmentation of 18 IVUS pullbacks show that the proposed procedure is fast and robust leading to 90% of time reduction with the same characterization performance.
منابع مشابه
Automatic segmentation and 3D reconstruction of intravascular ultrasound images for a fast preliminar evaluation of vessel pathologies
Intravascular ultrasound (IVUS) imaging is used along with X-ray coronary angiography to detect vessel pathologies. Manual analysis of IVUS images is slow and time-consuming and it is not feasible for clinical purposes. A semi-automated method is proposed to generate 3D reconstructions from IVUS video sequences, so that a fast diagnose can be easily done, quantifying plaque length and severity ...
متن کاملOptimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement
Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...
متن کاملFabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...
متن کاملComparison between optical coherence tomography and intravascular ultrasound in detecting neointimal healing patterns after stent implantation.
BACKGROUND The amount of data comparing intravascular ultrasound (IVUS) and optical coherence tomography (OCT) for the detection of stent coverage in clinical settings is limited. AIM To make a qualitative and quantitative assessment of the vascular healing patterns in patients after stent implantations visualised by both IVUS and OCT. METHODS Images were obtained in patients with clinical ...
متن کاملAutomatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images
Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...
متن کامل