Evaluation of a Neck-Shield for Use During Neurological Studies with a Whole-Body PET Scanner

نویسندگان

  • C J Thompson
  • S Boelen
چکیده

It is well known that the shielding against out-of-field scattered radiation is not very effective on whole body PET scanners operated with their slice-defining septa retracted. Additional shielding can be employed during neurological studies since the diameter of the head is much less than the field of view required for imaging the human torso. We have designed, built and tested (on the CTI HR+ PET scanner) a new lead-plate shielding system which mounts on the scanner’s removable head-rest. We call this device the “NeuroShield”. The outer diameter of the 9 mm thick lead plate is 550 mm which has a “U” shaped hole 220 mm in diameter. It is positioned just above the subject’s shoulders. A moulded plastic coupling piece, produced by stereolithography, was designed to accommodate the complex shape of the headrest under the subject’s neck, and provide a flat surface for mounting the lead plate. Our testing on human subjects involved comparing the prompt and random count rates and dead time during bolus-water activation studies. Scans on different subjects, (matched for age and sex) with no additional shielding, with the CTI Neurological Insert, and with the NeuroShield were compared. The random counts were reduced by a factor of 1.56 when using the permanent CTI Neurological Insert, and 1.44 using the NeuroShield. The NeuroShield is easily removed to allow whole body scanning. It can remain in place as the couch extends through the scanning tunnel in the gantry. Its main application will be at PET centres doing a mixture of whole body and neurological studies, where the CTI Neurological Insert cannot be installed permanently.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST

Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...

متن کامل

Value of Dedicated Head and Neck 18F-FDG PET/CT Protocol in Detecting Recurrent and Metastatic Lesions in Post-surgical Differentiated Thyroid Carcinoma Patients with High Serum Thyroglobulin Level and Negative 131I Whole-body Scan

Objective(s): In clinical practice, approximately 10-25% of post-surgical differentiated thyroid carcinoma (DTC) patients with high serum thyroglobulin (Tg) and negative 131I whole-body scan (WBS) have poor prognosis due to recurrent or metastatic lesions after radioactive iodine treatment. The purpose of this study was to evaluate the value of 18F-FDG PET/CT scan in DTC patients with high seru...

متن کامل

Systemic atherosclerotic plaque vulnerability in patients with Coronary Artery Disease with a single Whole Body [FDG]PET-CT scan

Objective(s): Cardiovascular disease is a leading cause of morbimortality with over half cardiovascular events occurring in the asymptomatic population by traditional risk stratification. This preliminary study aimed to evaluate systemic plaque vulnerability in patients with prior Coronary Artery Disease (CAD) with a single Whole Body [FDG] PET-CT scan in terms of plaq...

متن کامل

New Metal Shield for the Endotracheal Tube during Laser Endolaryngeal Surgery

Introduction: To present and assess a newly designed autoclavable, reusable tube shield for an endotracheal tube (ETT) during laser laryngeal surgery.   Materials and Methods: This study included patients scheduled for endolaryngeal laser surgery. A carbonated stainless-steel hemisphere shield (~1.5×0.6 mm) connected to a silk thread passing through a hole in its middle near upper edge was ...

متن کامل

Validation and evaluation of a GATE model for MAMMI PET scanner

Introduction:MAMMI is a dedicated PET based on high resolution detectors placed close to the breast. In this study, we presented a GATE model for the simulation of MAMMI scanner and model its performance of the MAMMI based on an adaptation of the NU 4-2008 NEMA standard.  Methods:A detailed of geometry MAMMI system that uses scintillation crystals coupled...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000