Optimal Control of a Magnetic Bearing without Bias Flux Using Finite Voltage

نویسندگان

  • Charles Yang
  • Panagiotis Tsiotras
چکیده

Conventional Active Magnetic Bearings (AMB) are operated using a bias current (or flux) to achieve greater linearity and dynamic capability. Bias, however, results in undesirable rotating losses and consequent rotor heating. While control without bias flux is an attractive alternative, it is considerably more complex due to both force slew rate limitations and actuator nonlinearity. In this paper, optimal control of a magnetic bearing without bias is investigated. A single degree-of-freedom system consisting of a mass and two opposing electromagnets is considered. The optimal control problem is examined for a cost function that penalizes both poor regulation and rotational energy lost. Though a standard optimization procedure does not directly yield an analytical solution, it does show that the optimal control is always bang-bang including possibly a singular arc. First, the minimum time problem is solved for a simple switching law in three dimensional state space. A non-standard, physics-based approach is then employed to obtain an optimal solution for the general problem. The final result is an optimal variable structure feedback controller. This result provides a benchmark which can be used for evaluation of the performance of a practical feedback controller designed via other methods. The practical controller will be designed to support a flexible rotor and achieve robustness and optimally reject disturbance. This result may also be applied to many other applications which contain opposing quadratic actuators.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Control of a Magnetic Bearing without Bias Flux

Conventional Active Magnetic Bearings (AMB) are operated using a bias current (or flux) to achieve greater linearity and dynamic capability. Bias, however, results in undesirable rotating losses and consequent rotor heating. In this paper, optimal control of a magnetic bearing without bias is investigated. A single degree-of-freedom system consisting of a mass and two opposing electromagnets is...

متن کامل

Implementation of the Generalized Complementary Flux Constraint for Low-Loss Active Magnetic Bearings

This paper explores the experimental issues associated with the implementation of the recently developed generalized complementary flux constraint (GCFC) flux-biasing scheme on a spacecraft reaction wheel that is magnetically suspended by a low-loss active magnetic bearing (AMB). Implementation of the GCFC depends fundamentally on the ability to estimate the electromagnet flux. Once addressed, ...

متن کامل

Using an Appropriate Controller for Independent Current Control for Motoring of Force Windings of Bearing less Induction Motor

A bearingless induction machine has combined characteristics of induction motor and magnetic bearings. Therefore, the advantages are small size and low-cost. In the magnetic suspension of the bearingless motors, suspension forces are generated based on the feedback signals of displacement sensors detecting the movement of the rotor shaft. The suspension forces are generated taking an advantage ...

متن کامل

Magnetic Bearing Rotordynamic System Optimization Using Multi-Objective Genetic Algorithms

Multiple objective genetic algorithms (MOGAs) simultaneously optimize a control law and geometrical features of a set of homopolar magnetic bearings (HOMB) supporting a generic flexible, spinning shaft. The minimization objectives include shaft dynamic response (vibration), actuator mass and total actuator power losses. Levitation of the spinning rotor and dynamic stability are constraint condi...

متن کامل

Optimized Realization of Fault-Tolerant Heteropolar Magnetic Bearings

Flux coupling in heteropolar magnetic bearings permits remaining active coils to assume actions of failed coils to produce force resultants identical to the un-failed actuator. This fault-tolerant control usually reduces load capacity because the redistribution of the magnetic flux which compensates for the failed coils leads to premature saturation in the stator or journal. A distribution matr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998