Characterization of ion processes in a GC/DMS air quality monitor by integration of the instrument to a mass spectrometer.

نویسندگان

  • T F Limero
  • E G Nazarov
  • M Menlyadiev
  • G A Eiceman
چکیده

The air quality monitor (AQM), which included a portable gas chromatograph (GC) and a detector was interfaced to a mass spectrometer (MS) by introducing flow from the GC detector to the atmospheric pressure ion source of the MS. This small GC system, with a gas recirculation loop for carrier and detector make-up gases, comprised an inlet to preconcentrate volatile organic compounds (VOCs) in air, a thermal desorber before the GC column, a differential mobility spectrometer (DMS), and another DMS as an atmospheric pressure ionization source for the MS. Return flow to the internally recirculated air system of the AQM's DMS was replenished using purified air. Although ions and unreacted neutral vapors flowed from the detector through Viton® tubing into the source of the MS, ions were not detected in the MS without the auxillary ion source, (63)Ni as in the mobility detector. The GC-DMS-MS instrument provided a 3-D measurement platform (GC, DMS, and MS analysis) to explore the gas composition inside the GC-DMS recirculation loop and provide DMS-MS measurement of the components of a complex VOC mixture with performance significantly enhanced by mass-analysis, either with mass spectral scans or with an extracted ion chromatogram. This combination of a mobility spectrometer and a mass spectrometer was possible as vapors and ions are carried together through the DMS analyzer, thereby preserving the chromatographic separation efficiency. The critical benefit of this instrument concept is that all flows in and through the thoroughly integrated GC-DMS analyzer are kept intact allowing a full measure of the ion and vapor composition in the complete system. Performance has been evaluated using a synthetic air sample and a sample of airborne vapors in a laboratory. Capabilities and performance values are described using results from AQM-MS analysis of purified air, ambient air from a research laboratory in a chemistry building, and a sample of synthetic air of known composition. Quantitative measures of a stand-alone AQM are disclosed for VOCs in the ppb to ppm levels with an average precision of 5.8% RSD and accuracy from 4% to 28% error against a standard method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Evaluation of a benchtop capillary gas chromatograph-mass spectrometer for clinical toxicology.

We evaluated the Hewlett-Packard 5995B benchtop capillary gas chromatograph-mass spectrometer (GC-MS) for its ability to identify drugs commonly detected and (or) measured in the clinical toxicology laboratory. Initial experiments indicated that the instrument as originally configured, with an isolation valve between the gas chromatograph and mass spectrometer, was unsatisfactory for the identi...

متن کامل

The Development and Validation of an Analytical Method for Simultaneous Determination of Amitraz and Its Metabolite in Air Samples

Background: To determine the atmospheric contamination by pesticides, conducting laboratory studies is necessary before operating field studies. The aim of this research study was to develop an analytical method to sample and simultaneously determine airborne amitraz and its metabolite. Methods: A modified fritted impinger with acetonitrile as the liquid sorbent was used in order to study the...

متن کامل

Study of the traces of nature in herbal deposits of a thousand-year-old Alembic glass analyzed and processed by the Gas Chromatography-Mass Spectrometer (GC-MS).

During the Islamic periods, the containers characterized by narrow or pear-shaped glass-body with a round bottom and long drainage pipe or tube were known, but rarely have been studied. There are three different hypotheses for applications of such containers. A cupping glass(Shakh-i hajamat) for phlebotomize in medicine, “Alembic” for chemical or alchemical experiments, or containers for pharma...

متن کامل

Partial Purification and Characterization of the Recombinant Benzaldehyde Dehydrogenase from Rhodococcus ruber UKMP-5M

Background: Benzaldehyde dehydrogenase (BZDH) is encoded by the xylC that catalyzes the conversion of benzaldehyde into benzoate in many pathways such as toluene degradation. Objectives: In this study, the xylC gene from Rhodococcus ruber UKMP-5M was expressed in Escherichia coli, purified, and characterized.Materials and Methods: The xylC was amplified and cloned in E. coli. The re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 140 3  شماره 

صفحات  -

تاریخ انتشار 2015