Application of Hadamard transform to gas chromatography/nonresonant multiphoton ionization/time-of-flight mass spectrometry.

نویسندگان

  • Chao-Chiang Cheng
  • Hung-Wei Chang
  • Tomohiro Uchimura
  • Totaro Imasaka
  • Takashi Kaneta
  • Cheng-Huang Lin
چکیده

The technique of Hadamard transform was successfully coupled with GC/nonresonant multiphoton ionization/TOFMS, for the first time. 1,4-Dichlorobenzene and the fourth harmonic generation (266 nm) of a Nd:YAG laser were employed as a model sample and an ionization laser, respectively. A Hadamard-injector coupled with a capillary-based supersonic jet nozzle (capillary-injector) was also developed in this study. The Hadamard-injector was used to obtain the chromatogram, which was encoded by successive sample introduction based on Hadamard codes, and the capillary-injector was used for injection of GC-elutes into TOFMS. Compared with a conventional single injection method, the S/N ratios were substantially improved after inverse Hadamard transformation of the encoded chromatogram. Under optimized conditions, when Hadamard matrices of 103 and 255 were used, the S/N ratios of the signals for 1,4-dichlorobenzene (concentration level, 4 microg/1 mL ACN) were substantially improved to 4.1- and 6.6-fold, respectively, and those improvements are in good agreement with those obtained by theory (5.1- and 8.0-fold).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Analysis of persistent organic pollutants at sub-femtogram levels using a high-power picosecond laser for multiphoton ionization in conjunction with gas chromatography/time-of-flight mass spectrometry.

A low-energy, high-repetition-rate picosecond laser (40 µJ, 20 kHz, 258 nm) was used for multiphoton ionization (MPI) in gas chromatography/time-of-flight mass spectrometry to quantitatively determine dioxins (DXNs) and polycyclic aromatic hydrocarbons (PAHs). The sensitivity of the technique was compared with that obtained using a high-energy, low-repetition-rate femtosecond laser (86 µJ, 1 kH...

متن کامل

Gas chromatography/multiphoton ionization/time-of-flight mass spectrometry using a femtosecond laser.

A laser can be used for the selective excitation and subsequent ionization of a molecule with an absorption band at the laser wavelength. This technique of multiphoton ionization (MPI), when combined with time-of-flight mass spectrometry (TOF-MS), permits the efficient detection of induced ions in mass analysis. This combination of MPI/TOF-MS can be coupled with gas chromatography (GC) to achie...

متن کامل

Trace analysis of polycyclic aromatic hydrocarbons using gas chromatography-mass spectrometry based on nanosecond multiphoton ionization.

Gas chromatography/resonance-enhanced multiphoton ionization/time-of-flight mass spectrometry (GC/REMPI-TOFMS) using an ultraviolet nanosecond laser was employed in the trace analysis of polycyclic aromatic hydrocarbons (PAHs). A standard sample that contained 16 PAHs on the priority list of the Environmental Protection Agency of the United States of America (U.S. EPA) was measured. A sample of...

متن کامل

Applications of Hadamard transform to gas chromatography/mass spectrometry and liquid chromatography/mass spectrometry.

Successful application of the Hadamard transform (HT) technique to gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS) is described. Novel sample injection devices were developed to achieve multiple sample injections in both GC and LC instruments. Air pressure was controlled by an electromagnetic valve in GC, while a syringe pump and Tee connector we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of separation science

دوره 33 4-5  شماره 

صفحات  -

تاریخ انتشار 2010