Reconstruction of the esophagojejunostomy by double stapling method using EEA™ OrVil™ in laparoscopic total gastrectomy and proximal gastrectomy

نویسندگان

  • Noriyuki Hirahara
  • Hiroyuki Monma
  • Yoshihide Shimojo
  • Takeshi Matsubara
  • Ryoji Hyakudomi
  • Seiji Yano
  • Tsuneo Tanaka
چکیده

Here we report the method of anastomosis based on double stapling technique (hereinafter, DST) using a trans-oral anvil delivery system (EEATM OrVilTM) for reconstructing the esophagus and lifted jejunum following laparoscopic total gastrectomy or proximal gastric resection. As a basic technique, laparoscopic total gastrectomy employed Roux-en-Y reconstruction, laparoscopic proximal gastrectomy employed double tract reconstruction, and end-to-side anastomosis was used for the cut-off stump of the esophagus and lifted jejunum. We used EEATM OrVilTM as a device that permitted mechanical purse-string suture similarly to conventional EEA, and endo-Surgitie. After the gastric lymph node dissection, the esophagus was cut off using an automated stapler. EEATM OrVilTM was orally and slowly inserted from the valve tip, and a small hole was created at the tip of the obliquely cut-off stump with scissors to let the valve tip pass through. Yarn was cut to disconnect the anvil from a tube and the anvil head was retained in the esophagus. The end-Surgitie was inserted at the right subcostal margin, and after the looped-shaped thread was wrapped around the esophageal stump opening, assisting Maryland forceps inserted at the left subcostal and left abdomen were used to grasp the left and right esophageal stump. The surgeon inserted anvil grasping forceps into the right abdomen, and after grasping the esophagus with the forceps, tightened the end Surgitie, thereby completing the purse-string suture on the esophageal stump. The main unit of the automated stapler was inserted from the cut-off stump of the lifted jejunum, and a trocar was made to pass through. To prevent dropout of the small intestines from the automated stapler, the automated stapler and the lifted jejunum were fastened with silk thread, the abdomen was again inflated, and the lifted jejunum was led into the abdominal cavity. When it was confirmed that the automated stapler and center rod were made completely linear, the anvil and the main unit were connected with each other and firing was carried out. Then, DST-based anastomosis was completed with no dog-ear. The method may facilitate safe laparoscopic anastomosis between the esophagus and reconstructed intestine. This is also considered to serve as a useful anastomosis technique for upper levels of the esophagus in laparotomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laparoscopic total gastrectomy using the transorally inserted anvil (OrVil™): a preliminary, single institution experience

Laparoscopic total gastrectomy (LTG) is not a commonly performed procedure due to the difficulty associated with surgical reconstruction. We present our preliminary results after intracorporeal circular stapling esophagojejunostomy using the newly developed transorally inserted anvil (OrVil™, Covidien, MA, USA). Between 2008 and June 2013, 51 patients underwent laparoscopic gastrectomy with D2 ...

متن کامل

Safety of intracorporeal circular stapling esophagojejunostomy using trans-orally inserted anvil (OrVil™) following laparoscopic total or proximal gastrectomy - comparison with extracorporeal anastomosis

BACKGROUND There have been several attempts to develop a unique and easier way to perform esophagojejunostomy during laparoscopy-assisted total gastrectomy or laparoscopy-assisted proximal gastrectomy. The OrVil system (Covidien, Mansfield, MA, USA) is one of those methods, but its technical and oncologic feasibility have not been proven and need to be observed. METHODS Among 87 patients who ...

متن کامل

Comparison of Short-term and Long-term Clinical Outcomes Between Laparoscopic and Open Total Gastrectomy for Patients With Gastric Cancer

BACKGROUND AND PURPOSE Validation of laparoscopic total gastrectomy (LTG) for patients with gastric cancer has not been fully investigated. In particular, the technique for esophagojejunostomy remains controversial. We performed 103 cases of LTG for patients with gastric cancer between 2007 and 2013, in which all esophagojejunostomy reconstruction was performed with intracorporeal circular stap...

متن کامل

Outcome of esophagojejunostomy during totally laparoscopic total gastrectomy: a single-center retrospective study.

AIM The present study aimed to clarify the safety and feasibility of esophagojejunostomy during totally laparoscopic total gastrectomy (TLTG). PATIENTS AND METHODS In 45 consecutive patients who underwent TLTG for gastric cancer, esophagojejunostomy was performed with a functional end-to-end anastomosis (FEEA) using a linear stapler in 24 patients or with a double stapling technique (DST) usi...

متن کامل

An automatically contamination-avoiding technique for intracorporeal esophagojejunostomy using a transorally inserted anvil during laparoscopic total gastrectomy for gastric cancer

BACKGROUND Intracorporeal Roux-en-Y esophagojejunostomy during laparoscopic total gastrectomy for gastric cancer remains a challenging manipulation due to the uncontrolled direction of the jejunal side or unintended embedded tissues, although several methods have been introduced. In this study, we simplified the procedure based on a surgical string fixing technique using a transorally inserted ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2011